Related Experiment Video
Updated: Aug 15, 2025

Three-Dimensional Phase Resolved Functional Lung Magnetic Resonance Imaging
Published on: June 21, 2024
Free-breathing 3D Stack-of-Stars Gradient Echo Sequence in MR-guided Percutaneous Liver Interventions: Evaluation of
Julian Glandorf1, Dominik Horstmann2, Daniel Markus Düx2
1Institute for Diagnostic and Interventional Radiology, Hannover Medical School, Carl-Neuberg-Str. 1, 30625, Hannover, Germany. glandorf.julian@mh-hannover.de.
Purpose:
To evaluate workflow efficiency and diagnostic quality of a free-breathing 3D stack-of-stars gradient echo (Radial GRE) sequence compared to a breath-hold 3D Cartesian gradient echo (Cartesian GRE) sequence for needle position control in MR-guided liver interventions.
Materials And Methods:
12 MR-guided liver interventions were performed on a 1.5 T Siemens Aera and analyzed retrospectively. 15 series of the Radial GRE sequence were compared to 14 series of the Cartesian GRE sequence regarding the time interval between two consecutive live-scans for needle tracking (Tracking-2-Tracking-Time). The quality of both sequences was compared by the SNR within comparable slices in liver and tumor ROIs. The CNR was calculated by subtraction of the SNR values. Subjective image quality scores of three radiologists were assessed and inter-rater reliability was tested by Fleiss' kappa. Values are given as mean ± SD. P-values < 0.05 were considered as significant.
Results:
The median Tracking-2-Tracking-Time was significantly shorter for the Radial GRE sequence, 185 ± 42 s vs. 212 ± 142 s (p = 0.04) and the median SNR of the liver and tumor ROIs were significantly higher in the Radial GRE sequence, 249 ± 92 vs. 109 ± 67 (p = 0.03) and 165 ± 74 vs. 77 ± 43 (p = 0.02). CNR between tumor and liver ROIs showed a tendency to be higher for the Radial GRE sequence without significance, 68 ± 48 vs. 49 ± 32 (p = 0.28). Mean subjective image quality was 3.33 ± 1.08 vs. 2.62 ± 0.95 comparing Radial and Cartesian GRE with a Fleiss' kappa of 0.39 representing fair inter-rater reliability.
Conclusion:
A free-breathing 3D stack-of-stars gradient echo sequence can simplify the workflow and reduce intervention time, while providing superior image quality. Under local anesthesia, it increases patient comfort and reduces potential risks for needle dislocations in MR-guided liver interventions by avoiding respiratory arrests for needle position control.
More Related Videos
Related Concept Videos
Imaging Studies for Cardiovascular System IV: CMRI
Radiological Investigation II: MRI and Ventilation Perfusion Scan
Magnetic Resonance Imaging (MRI) and Ventilation Perfusion Scans are two radiological investigations that offer detailed diagnostic images of the body, particularly lung structures.
MRI
MRI uses magnetic fields and radiofrequency signals to distinguish between normal and abnormal tissues. This technology provides a more detailed diagnostic image than CT scans, enabling it to characterize pulmonary nodules, stage bronchogenic carcinoma, and evaluate inflammatory activity in...

