Related Experiment Video
Updated: Aug 15, 2025

Author Spotlight: 3D Movement Assessment of Maxillary Posterior Teeth in Clear Aligner Treatment
Published on: February 23, 2024
Evaluation of two different occlusal patterns on single posterior implant-supported crowns: A 12-month prospective
Ru Zhang1, Xiaoyu Hao2, Kaiyu Zhang3
1Attending, Department of Prosthodontics, Capital Medical University School of Stomatology, Beijing Stomatological Hospital, Beijing, PR China.
Statement Of Problem:
According to the concept of implant-protected occlusion, light occlusion and late contact could prevent implants from occlusal overload. However, clinical data demonstrating how light occlusion differs from normal occlusion are lacking.
Purpose:
The purpose of this prospective clinical study was to characterize the occlusal variation of single posterior implant-supported crowns with or without light occlusion.
Material And Methods:
Participants with a single missing posterior maxillary or mandibular molar who were to receive implant-supported zirconia ceramic crowns were enrolled. The participants were divided into a light occlusion group, in which a 12-μm articulating film could be removed from the implant-supported crown and opposing natural teeth under the intercuspal position, and a normal occlusion group, in which the articulating film could not be removed. All participants underwent occlusal examinations using the T-scan III system, answered a satisfaction questionnaire using a visual analog scale (VAS), and received regular follow-ups. The participants were evaluated at 0.5, 3, 6, and 12 months after implant-supported crown delivery. The relative occlusal force of the implant-supported crowns, mesial teeth, control teeth (corresponding natural tooth on the dentition contralateral to each implant), and the occlusal contact time of implant-supported crowns were recorded. Moreover, the asymmetry index of the occlusal force and the VAS score were calculated. Two independent-sample tests were used to compare the 2 groups. The Wilcoxon rank sum and Mann‒Whitney tests were used to compare nonnormally distributed data (α=.001).
Results:
Fifty study participants with a mean ±standard deviation age of 36.97 ±7.34 years (23 men and 27 women aged 20 to 50 years) were followed for 0.5 to 12 months. No obvious complications of overloading were observed in either group. The mean ±standard deviation of the relative occlusal force of implant-supported crowns in the light occlusion group (from 4.91 ±3.52% to 10.34 ±4.35%) was always lower than that in the normal occlusion group (from 10.45 ±4.32% to 18.15 ±4.80%), while the mean ±standard deviation of the occlusal contact time in the light occlusion group (from 0.38 ±0.26 seconds to 0.10 ±0.07 seconds) was significantly later than that in the normal occlusion group (from 0.12 ±0.08 seconds to 0.04 ±0.02 seconds) (P<.001). The value of the asymmetry index of occlusal force remained within the normal range (10%). The VAS score in the normal occlusion group was significantly higher than that in the light occlusion group (P<.001).
Conclusions:
Providing light occlusion to reduce occlusal force and delay the contact time was not stable over time. The relative occlusal force and occlusal contact time showed a similar development trend in both groups, and no obvious signs of occlusal overloading were observed in this study. Long-term follow-up is necessary for implant-supported prostheses because of the continuous increase in occlusal force.

