Mesoscale Numerical Analysis of Fiber-Reinforced Sand with Different Fiber Orientations Subjected to Seepage-Induced
Shengtao Yang1, Yan Lv1, Yuanyuan He1
1College of Construction Engineering, Jilin University, Changchun 130026, China.
Abstract:
This paper focuses on the effect of fiber orientation on the resistance of seepage-induced erosion in fiber-reinforced sand. To clarify the discrepancy and mechanism of different-oriented fibers improving the resistance of the sand matrix, a series of DEM-Darcy coupling simulations were conducted. The microscopic parameters of fiber-reinforced sand were confirmed by the rigorous calibration procedure. The fibers perpendicular to the seepage direction were found to increase the difficulty of moving fluid through the specimen and significantly reduce the erosion rate of the specimen. These macroscopic behaviors acquired corresponding explanations at the mesoscopic scale, including the evolution of fiber-sand contact orientation, coordination number, average normal contact force, tensile force, and energy dissipation. According to the simulation results, it is found that the highest proportion of tensile force in perpendicular fibers can reach 80%, while the parallel fibers are only 40%, which indicates that the perpendicular fibers have a significant netting effect. The mesoscopic behaviors reasonably revealed the role of the fibers with different orientations on the sand matrix during the seepage. This study is beneficial for further understanding the mechanical behaviors of fiber-reinforced sand under seepage-induced erosion in safety engineering.
More Related Videos
Related Concept Videos
Fineness Modulus
Consider performing sieve analysis on sand through a set of ASTM sieves. The weight of aggregate retained in each sieve and pan placed at the bottom is recorded, as given in Column B of Table 1.
To determine the fineness modulus of...
Dynamic Modulus of Elasticity of Concrete
The sonic test is a common method to determine the dynamic modulus. In this test, a concrete beam, sized either 6 x 6 x 30 inches or 4 x 4 x 20 inches, is clamped at its center. Vibrations are initiated at one end of the beam by an electromagnetic exciter unit powered by...
Design Example: Aggregate Gradation
The grading, or particle-size distribution, of sand is determined using sieve analysis, with standard sizes ranging from 150 μm to 10 mm (ASTM No. 100 sieve to 3⁄8 in. sieve). Sand is...
Fiber Reinforced Concrete
Sieve Analysis and Grading Curves
Elasticity in Concrete