Related Experiment Video
Updated: Aug 14, 2025

Gas Chromatography-Mass Spectrometry Paired with Total Vaporization Solid-Phase Microextraction as a Forensic Tool
Published on: May 25, 2021
Solid-phase microextraction Arrow combined with comprehensive two-dimensional gas chromatography-mass spectrometry
Natalia Manousi1,2, Natasa Kalogiouri1,2, Antonio Ferracane3,4
1Laboratory of Analytical Chemistry, Department of Chemistry, Aristotle University of Thessaloniki, 54124, Thessaloniki, Greece.
Abstract:
In this work, a solid-phase microextraction (SPME) Arrow method combined with comprehensive two-dimensional gas chromatography-mass spectrometry (GC × GC-MS) was developed for the elucidation of the volatile composition of honey samples. The sample preparation protocol was optimized to ensure high extraction efficiency of the volatile organic compounds (VOCs) which are directly associated with the organoleptic properties of honey and its acceptance by the consumers. Following its optimization, SPME Arrow was compared to conventional SPME in terms of sensitivity, precision, and number of extracted VOCs. The utilization of SPME Arrow fibers enabled the determination of 203, 147, and 149 compounds in honeydew honey, flower honey, and pine honey, respectively, while a significantly lower number of compounds (124, 94, and 111 for honeydew honey, flower honey, and pine honey, respectively) was determined using conventional SPME. At the same time, the utilization of SPME Arrow resulted in enhanced sensitivity and precision. All things considered, SPME Arrow and GC × GC-MS can be considered as highly suitable for the elucidation of the volatile composition of complex food samples resulting in high sensitivity and separation efficiency.
More Related Videos
05:22Rapid Collection of Floral Fragrance Volatiles using a Headspace Volatile Collection Technique for GC-MS Thermal Desorption Sampling
Published on: December 10, 2019
08:10Fizzy Extraction of Volatile Organic Compounds Combined with Atmospheric Pressure Chemical Ionization Quadrupole Mass Spectrometry
Published on: July 14, 2017
Related Concept Videos
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall....
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a...
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...
Gas Chromatography: Types of Columns and Stationary Phases
For an analyte to remain on the column for a sufficient amount of time, it must exhibit some level of compatibility (or...
Gas Chromatography: Types of Detectors-II
Gas Chromatography: Sample Injection Systems
Two primary injection methods are used...