Related Experiment Video
Updated: Aug 14, 2025

Assessment of Pulmonary Capillary Blood Volume, Membrane Diffusing Capacity, and Intrapulmonary Arteriovenous Anastomoses During Exercise
Published on: February 20, 2017
Peak Cardiac Output Determined Using Inert Gas Rebreathing: A Comparison of Two Exercise Protocols
William Bostad1, Devin G McCarthy1, Douglas L Richards2
1Department of Kinesiology, McMaster University, Hamilton, Ontario, CANADA.
Purpose:
This study aimed to compare Q˙peak elicited by a constant load protocol ( Q˙CL ) and an incremental step protocol ( Q˙step ).
Methods:
A noninferiority randomized crossover trial was used to compare Q˙peak between protocols using a noninferiority margin of 0.5 L·min -1 . Participants ( n = 34 (19 female, 15 male); 25 ± 5 yr) performed two baseline V̇O 2peak tests to determine peak heart rate (HR peak ) and peak work rate ( Wpeak ). Participants then performed the Q˙CL and Q˙step protocols each on two separate occasions with the order of the four visits randomized. Q˙peak was measured using IGR (Innocor; COSMED, Rome, Italy). The Q˙CL protocol involved a V̇O 2peak test followed 10 min later by cycling at 90% Wpeak , with IGR initiated after 2 min. Q˙step involved an incremental step test with IGR initiated when the participant's HR reached 5 bpm below their HR peak . The first Q˙CL and Q˙step tests were compared for noninferiority, and the second series of tests was used to measure repeatability (typical error (TE)).
Results:
The Q˙CL protocol was noninferior to Q˙step ( Q˙CL = 17.1 ± 3.2, Q˙step = 16.8 ± 3.1 L·min -1 ; 95% confidence intervals, -0.16 to 0.72 L·min -1 ). The baseline V̇O 2peak (3.13 ± 0.83 L·min -1 ) was achieved during Q˙CL (3.12 ± 0.72, P = 0.87) and Q˙step (3.12 ± 0.80, P = 0.82). The TE values for Q˙peak were 6.6% and 8.3% for Q˙CL and Q˙step , respectively.
Conclusions:
The Q˙CL protocol was noninferior to Q˙step and may be more convenient because of the reduced time commitment to perform the measurement.
More Related Videos
Related Concept Videos
Exercise and Cardiac Output
Sustained exercise increases the muscles' oxygen demand, which can be...
Cardiac Output I:Effect of Heart Rate on Cardiac Output
Cardiac output (CO) refers to the total amount of blood ejected by one of the ventricles in liters per minute (L/min). In a resting adult, CO ranges from 5 to 6 L/min, adjusting according to the body's metabolic requirements.
Effect of Heart Rate on Cardiac Output
Cardiac output adapts to metabolic demands during stress, physical activity, or illness. The autonomic nervous system regulates heart rate via the sinoatrial node. The parasympathetic nervous system decreases heart...
Cardiac Output and Stroke Volume
In an average resting adult male, the typical cardiac...
Cardiac Output II: Effect of Stroke Volume on Cardiac Output
Preload
Preload refers to the initial elongation of the cardiac myocytes before contraction and is related to the volume of blood filling the heart at the end of diastole, or end-diastolic volume. The...
Exercise and Cardiovascular Response
Light to moderate physical activity initiates a series of interconnected responses in the body. The heart rate modestly increases in anticipation of the workout, followed by widespread vasodilation as oxygen consumption by skeletal muscles increases. This results in decreased peripheral resistance, increased capillary blood flow, and accelerated...