Related Experiment Video
Updated: Aug 14, 2025

Author Spotlight: Advancing Research on Candida albicans Biofilm-Associated Prosthetic Joint Infections
Published on: February 2, 2024
Risk factors associated with higher mortality in patients with cardiac implantable electronic device infection
Mohamad A Kalot1, Ronak Bahuva1, Rohan Pandey1
1Department of Medicine, Clinical & Translational Research Center, Buffalo, New York, USA.
Insights
Cardiac Implantable Electronic Device Infections (CIED-I) carry high mortality. Key risk factors for death include hypertension, end-stage renal disease, immunosuppression, and referral from regional facilities, highlighting the need for early risk assessment.
Area of Science:
- Cardiology
- Infectious Diseases
- Public Health
Background:
- Cardiac Implantable Electronic Devices (CIEDs) are crucial for managing heart failure and arrhythmias.
- Cardiac Implantable Electronic Device Infections (CIED-I) are associated with high mortality, particularly in underserved populations.
- Identifying mortality predictors in CIED-I patients is critical for improving outcomes.
Purpose of the Study:
- To identify risk factors associated with mortality in patients diagnosed with CIED infections.
- To analyze clinical and demographic predictors of death in a cohort of CIED-I patients.
Main Methods:
- Retrospective cohort study of 296 patients with CIED-I from 2012-2020.
- Data collected from a regional database including patient demographics, infection sources, and clinical outcomes.
- Multivariate analysis used to determine associations between covariates and mortality risk.
Main Results:
- Male gender, white ethnicity, and a mean age of 69.2 years characterized the patient cohort.
- Staphylococcus aureus and Enterococcus fecalis were the most common pathogens.
- Significant mortality predictors included referral from regional facilities, hypertension, right ventricular dysfunction, end-stage renal disease, immunosuppression, and septic shock.
Conclusions:
- Hypertension, right ventricular dysfunction, immunosuppression, and end-stage renal disease independently increase mortality risk post-CIED-I.
- Patients referred from regional facilities experienced disproportionately higher mortality.
- Emphasizes the need for early clinical risk assessment and improved referral infrastructure to enhance patient survival rates.
Introduction:
Cardiac Implantable Electronic Devices (CIEDs) are widely used for the management of advanced heart failure and ventricular arrhythmias. CIED-Infection (CIED-I) has very high mortality, especially in the subsets of patients with limited health-care access and delayed presentation. The purpose of this study is to identify the risk-predictors mortality in subjects with CIED-I.
Methods:
We performed a retrospective cohort study of a regional database in patients presenting with CIED infections to tertiary care medical centers across Western New York, USA from 2012 to 2020. The clinical outcomes included recurrent device infection (any admission for CIED-I after the first hospitalization for device infection), septic complications (pulmonary embolism, respiratory failure, septic shock, decompensated HF, acute kidney injury) and mortality outcomes (death during hospitalization, within 30 days from CIED-I, and within 1 year from CIED-I). We studied associations between categorical variables and hard outcomes using χ2 tests and used one-way analysis of variance to measure between-groups differences.
Results:
We identified 296 patients with CIED-I, among which 218 (74%) were male, 237 (80%) were white and the mean age at the time of infection was 69.2 ± 13.7 years. One-third of the patients were referred from the regional facilities. Staphylococcus aureus was responsible for most infections, followed by Enterococcus fecalis. On multivariate analysis, the covariates associated with significantly increased mortality risk included referral from regional facility (OR: 2.0;1.0-4.0), hypertension (Odds ratio, OR: 3.2;1.3-8.8), right ventricular dysfunction (OR: 2.6;1.2-5.1), end-stage renal disease (OR: 2.6;1.1-6.2), immunosuppression (OR: 11.4;2.5-53.3), and septic shock as a complication of CIED-I (OR: 3.9;1.3-10.8).
Conclusion:
Hypertension, right ventricular dysfunction, immunosuppression, and end-stage renal disease are associated with higher mortality after CIED-I. Disproportionately higher mortality was also noted in subjects referred from the regional facilities. This underscores the importance of early clinical risk-assessment, and the need for a robust referral infrastructure to improve patient outcomes.
More Related Videos
16:40A New Single Chamber Implantable Defibrillator with Atrial Sensing: A Practical Demonstration of Sensing and Ease of Implantation
Published on: February 28, 2012
10:04A Zebrafish Embryo Model for In Vivo Visualization and Intravital Analysis of Biomaterial-associated Staphylococcus aureus Infection
Published on: January 7, 2019
Related Concept Videos
Endocarditis I: Introduction
Endocarditis III: Medical Management
Factors Affecting the Risk of Infection
The integrity and count of the white blood cells help the body resist pathogens and fight infection. When impaired, it reduces the body's resistance to pathogens. The acidic pH levels of the gastrointestinal, genitourinary tracts, and skin...
Endocarditis IV: Nursing Management
Endocarditis II: Clinical Features of Infective Endocarditis
Bacterial Signaling