Development of a voxel S-value database for patient internal radiation dosimetry
Lin Xin1, Weihai Zhuo1, Tianwu Xie1
1Institute of Radiation Medicine, Fudan University, 2094 Xietu Road Shanghai 200032, China.
Purpose:
Personalized dosimetry with high accuracy drew great attention in clinical practices. Voxel S-value (VSV) convolution has been proposed to speed up absorbed dose calculations. However, the VSV method is efficient for personalized internal radiation dosimetry only when there are pre-calculated VSVs of the radioisotope. In this work, we propose a new method for VSV calculation based on the developed mono-energetic particle VSV database of γ, β, α, and X-ray for any radioisotopes.
Methods:
Mono-energetic VSV database for γ, β, α, and X-ray was calculated using Monte Carlo methods. Radiation dose was first calculated based on mono-energetic VSVs for [F-18]-FDG in 10 patients. The estimated doses were compared with the values obtained from direct Monte Carlo simulation for validation of the proposed method. The number of VSVs used in calculation was optimized based on the estimated dose accuracy and computation time.
Results:
The generated VSVs showed a great consistency with the results calculated using direct Monte Carlo simulation. For [F-18]-FDG, the proposed VSV method with number of VSV of 9 shows the best relative average organ absorbed dose uncertainty of 3.25% while the calculation time was reduced by 99% and 97% compared to the Monte Carlo simulation and traditional multiple VSV methods, respectively.
Conclusions:
In this work, we provided a method to generate the VSV kernels for any radioisotope based on the pre-calculated mono-energetic VSV database and significantly reduced the time cost for the multiple VSVs dosimetry approach. A software was developed to generate VSV kernels for any radioisotope in 19 mediums.
More Related Videos
Related Concept Videos
Radiological Investigation II: MRI and Ventilation Perfusion Scan
Magnetic Resonance Imaging (MRI) and Ventilation Perfusion Scans are two radiological investigations that offer detailed diagnostic images of the body, particularly lung structures.
MRI
MRI uses magnetic fields and radiofrequency signals to distinguish between normal and abnormal tissues. This technology provides a more detailed diagnostic image than CT scans, enabling it to characterize pulmonary nodules, stage bronchogenic carcinoma, and evaluate inflammatory activity in...
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Radiological Investigation I: X-ray and CT
Biological Effects of Radiation
Radiation: Applications
The average...
Absorption of Radiation