Related Experiment Video
Updated: Aug 14, 2025

Surgical Retrieval, Isolation and In vitro Expansion of Human Anterior Cruciate Ligament-derived Cells for Tissue Engineering Applications
Published on: April 30, 2014
Failure modes after anterior cruciate ligament reconstruction: a systematic review and meta-analysis
Xiaoke Li1,2, Lei Yan1, Dijun Li1
1Department of Orthopaedic Surgery, Shanxi Medical University Second Affiliated Hospital, Taiyuan, China.
Purpose:
The reason for graft failure after anterior cruciate ligament reconstruction (ACLR) is multifactorial. Controversies remain regarding the predominant factor and incidence of failure aetiology in the literature. This review aimed to provide a meta-analysis of the literature to evaluate the relative proportion of various failure modes among patients with ACLR failure.
Methods:
The PubMed, Embase, Cochrane Library, Web of Science, and EBSCO databases were searched for literature on ACLR failure or revision from 1975 to 2021. Data related to causes for ACLR surgical failure were extracted, and a random effects model was used to pool the results, which incorporates potential heterogeneity. Failure modes were compared between different populations, research methods, graft types, femoral portal techniques, and fixation methods by subgroup analysis or linear regression. Funnel plots were used to identify publication bias and small-study effects.
Results:
A total of 39 studies were analyzed, including 33 cohort studies and six registry-based studies reporting 6578 failures. The results showed that among patients with ACLR failure or revision, traumatic reinjury was the most common failure mode with a rate of 40% (95% CI: 35-44%), followed by technical error (34%, 95% CI: 28-42%) and biological failure (11%, 95% CI: 7-15%). Femoral tunnel malposition was the most common cause of the technical error (29%, 95% CI: 18-41%), with more than two times higher occurrence than tibial tunnel malposition (11%, 95% CI: 6-16%). Traumatic reinjury was the most common factor for ACLR failure in European populations and in recent studies, while technical errors were more common in Asian populations, earlier studies, and surgery performed using the transtibial (TT) portal technique. Biological factors were more likely to result in ACLR failure in hamstring (HT) autografts compared to bone-patellar tendon-bone (BPTB) autografts.
Conclusion:
Trauma is the most important factor leading to surgical failure or revision following ACLR. Technical error is also an important contributing factor, with femoral tunnel malposition being the leading cause of error resulting in failure.
More Related Videos
05:44Author Spotlight: Double Posteromedial Approach for Treating Posterior Cruciate Ligament Cysts
Published on: October 20, 2023
05:07Author Spotlight: Implementing the Enhanced Recovery After Surgery Concept in Rehabilitation Following Anterior Cruciate Ligament Reconstruction
Published on: March 1, 2024
Related Concept Videos
Knee Joint
A total of seven ligaments support the knee joint. The patellar ligament, which is also attached to the quadriceps femoris...
Bones of the Lower Limb: Femur and Patella
Fractures: Bone Repair
Minor fractures with no bone displacement are treated by immobilizing the fractured bone using a cast or splint. However, in the case of fractures with displaced bones, the broken bones are repositioned before immobilization to ensure successful healing without deformation and loss of function. The realignment of fractured bone ends is performed through a process called reduction. If the...