Related Experiment Video
Updated: Aug 14, 2025

Brain Infarct Segmentation and Registration on MRI or CT for Lesion-symptom Mapping
Published on: September 25, 2019
Useful Test for Classification of Cerebral Infarction at Hospital Specializing in Neurosurgery
Hirotaka Yoshida1, Kazutoshi Nishitani2
1Department of Neurosurgery, Tokyo General Hospital, Tokyo, Japan.
Insights
Identifying the cause of cerebral infarction is crucial. Implantable cardiac monitors effectively detected paroxysmal atrial fibrillation in cryptogenic stroke cases, improving etiological classification.
Area of Science:
- Neurology
- Cardiology
- Medical Diagnostics
Background:
- Cerebral infarction of unknown etiology presents a diagnostic challenge, even after successful revascularization.
- Identifying embolic sources, such as atrial fibrillation, is critical for stroke management.
Purpose of the Study:
- To assess the significance of accurate disease classification in cerebral infarction.
- To investigate the causes of cryptogenic cerebral infarction.
Main Methods:
- Analysis of 556 consecutive cerebral infarction cases.
- Utilized Trials of Org 10172 in Acute Stroke Treatment (TOAST) classification.
- Implanted cardiac monitors in cryptogenic stroke patients.
Main Results:
- 94 cases (16.9%) classified as other/unknown etiology by TOAST.
- 22 of these cases had identified causes after further investigation.
- Implantable cardiac monitors detected paroxysmal atrial fibrillation in 26% of selected cryptogenic stroke cases.
Conclusions:
- Brain natriuretic peptide (BNP) measurement, CT scans, and cardiac monitoring aid in classifying cerebral infarction.
- Implantable cardiac monitors are valuable for detecting cryptogenic atrial fibrillation.
Abstract:
Background and Purpose: There are many cases of cerebral infarction of unknown etiology in which the embolic sources cannot be identified including atrial fibrillation despite achievement of complete revascularization after thrombectomy. Method: An analysis was conducted for 556 consecutive cases of patients who were hospitalized for cerebral infarction to determine the significance of accurate classification of disease type and investigation into causes of cerebral infarction of unknown cause. Result: According to the Trials of Org 10172 in Acute Stroke Treatment (TOAST) classification, cerebral infarction of other/unknown etiology was observed in 94 cases, of which 22 cases were found to have causes by additional workup. Implantable cardiac monitors were inserted in 15 of 76 cases of cryptogenic cerebral infarction, of which 4 cases (26%) showed detection of paroxysmal atrial fibrillation (PAF) during observation period (223-384 days). Conclusion: Brain natriuretic peptide (BNP) measurement, abdomen-pelvic computed tomography (CT), cardiac monitoring for 1 week, and implantable cardiac monitors (ICM) were useful for the classification of disease type and detection of cryptogenic atrial fibrillation. (This is secondary publication from J Jpn Coll Angiol 2021; 61: 49-55.).
More Related Videos
13:50Focal Cerebral Ischemia Model by Endovascular Suture Occlusion of the Middle Cerebral Artery in the Rat
Published on: February 5, 2011
12:42Stereological and Flow Cytometry Characterization of Leukocyte Subpopulations in Models of Transient or Permanent Cerebral Ischemia
Published on: December 28, 2014