Accuracy of a Professional Continuous Glucose Monitoring Device in Individuals with Type 2 Diabetes Mellitus
Yasushi Nakagawa1, Yushi Hirota1, Akane Yamamoto1
1Division of Diabetes and Endocrinology, Department of Internal Medicine, Kobe University Graduate School of Medicine, Kobe, Japan.
Abstract:
Among continuous glucose monitoring (CGM) devices, which continuously measure glucose concentration in subcutaneous interstitial fluid for comprehensive monitoring of blood glucose profile, only FreeStyle Libre Pro® (Abbott Diabetes Care) is currently available in Japan as a professional system. FreeStyle Libre Pro® is easy to use because it does not require calibration by self-monitoring of blood glucose (SMBG), but information on its accuracy has been insufficient. To evaluate the measurement accuracy of FreeStyle Libre Pro®, we have now compared blood glucose levels determined by this device with those measured by SMBG in 40 individuals with type 2 diabetes mellitus. The mean absolute relative difference (MARD) for FreeStyle Libre Pro® measurements compared with SMBG measurements was calculated as an index of CGM accuracy. Overall blood glucose values measured by SMBG were 167.0 ± 60.1 mg/dL, and those determined by FreeStyle Libre Pro® were 155.0 ± 60.7 mg/dL, with this difference being statistically significant. The MARD for FreeStyle Libre Pro® relative to SMBG was 12.7 ± 9.3%. It was substantially higher in 2 of the 40 patients, at 49.2% and 47.5%, than in the other 38 individuals. MARD values did not differ significantly between before and 2 h after meals. However, the MARD was significantly higher for SMBG values of <100 mg/dL than for those of ≥250 mg/dL. Our results thus indicate that the measurement accuracy of FreeStyle Libre Pro® is relatively good, but that some cases in which values determined by the device deviate from SMBG values require caution in interpretation.
Related Concept Videos
Diabetes Mellitus: Type 2 and Gestational
Diabetes Mellitus: Overview and Type I Subtype
Type 1 diabetes is an autoimmune disease in which the immune system mistakenly attacks and destroys the insulin-producing beta cells in the pancreas. As a result, the body is unable to produce sufficient insulin, and individuals with...
Carbohydrate Metabolism
Starch accounts for approximately 60% of the carbohydrates consumed by humans. Since amylase enzymes cannot function in the stomach's acidic environment, starch can only be digested in the mouth and small intestine. Simple sugars are found naturally in milk and fruits in...
Diabetes: Symptoms, Diagnosis, and Complications
Diabetes: Management and Pharmacotherapy
Insulin remains the cornerstone of treatment for most patients with type 1 and many...
Hypoglycemia and Glucagon