Related Experiment Video
Updated: Aug 14, 2025

E-Patient Counseling Trial E-PACO: Computer Based Education versus Nurse Counseling for Patients to Prepare for Colonoscopy
Published on: August 1, 2019
CO2 enterography in endoscopic retrograde cholangiography using double-balloon endoscopy: A randomized clinical trial
Kentaro Murate1, Masanao Nakamura1, Takeshi Yamamura1
1Department of Gastroenterology and Hepatology, Nagoya University Graduate School of Medicine, Nagoya, Japan.
Background And Aim:
Double-balloon endoscopic retrograde cholangiography (DBERC) is a valuable procedure for patients with altered gastrointestinal anatomy. Nonetheless, it is time-consuming and burdensome for both patients and endoscopists, partly because route selection in the reconstructed bowel with complicating loop is challenging. Carbon dioxide insufflation enterography is reportedly useful for route selection in the blind loop. This prospective randomized clinical trial investigated the usefulness of carbon dioxide insufflation enterography for route selection by comparing it with conventional observation.
Methods:
Patients scheduled to undergo DBERC were consecutively registered. They were divided into carbon dioxide insufflation enterography and conventional groups via randomization according to stratification factors, type of reconstruction methods, and experience with DBERC. The primary endpoint was the correct rate of initial route selection. The secondary endpoints were the insertion time, examination time, amount of anesthesia drugs, and complications.
Results:
The correct rate of route selection was significantly higher in the carbon dioxide insufflation enterography group (23/25, 92%) than in the visual method (15/25, 60%) (P = 0.018). The insertion time was significantly shorter in the carbon dioxide insufflation enterography group than in the visual group (10.8 ± 11.1 min vs 29.8 ± 15.7 min; P < 0.001). No significant differences in complications were noted between the two groups. The amounts of sedatives and analgesics used were significantly lower in the carbon dioxide insufflation enterography group (P < 0.001 and P < 0.001, respectively).
Conclusions:
Carbon dioxide insufflation enterography can reduce the burden of DBERC on patients and endoscopists by shortening the examination time and reducing the amount of medication.
More Related Videos
07:44Endoscopic Ultrasound-Guided Biliary Drainage: Endoscopic Ultrasound-Guided Hepaticogastrostomy in Malignant Biliary Obstruction
Published on: March 25, 2022
07:52Expired CO2 Measurement in Intubated or Spontaneously Breathing Patients from the Emergency Department
Published on: January 29, 2011
Related Concept Videos
Endoscopic Procedures V: ERCP
Patient...
Endoscopic Procedures I: Esophagogastroduodenoscopy
During an EGD, the endoscope can be used to:
Endoscopic Studies I: Bronchoscopy and Thoracoscopy
Bronchoscopy
Description
Bronchoscopy is a procedure that involves direct visualization of the larynx, trachea, and bronchi for diagnostic and therapeutic purposes. A flexible fiber optic or rigid bronchoscope is used to carry out the procedure. The fiber-optic bronchoscope is more frequently used due...
Assessment of Diffusion and Perfusion
The Role of Diffusion in Respiration
Diffusion is the process by which molecules move from an area of higher concentration to an area of lower concentration. In the respiratory system, this...
Endoscopic Studies II: Thoracocentesis
Description
Excess pleural fluid or air may accumulate in some respiratory disorders in the thoracic cavity. To treat pleural effusion, a physician conducts thoracentesis by carefully piercing the chest wall and entering...
Endoscopic Procedures III: Video Capsule Endoscopy