Contrasting effects of static and pulsatile pressure on carotid baroreceptor activity in dogs
1Cardiovascular Center, University of Iowa College of Medicine, Iowa City 52242.
Abstract:
The purpose of this study was to contrast the effects of static and pulsatile pressure on carotid baroreceptor activity over a wide range of mean arterial pressure. Static and pulsatile pressure were applied to the isolated carotid sinus of dogs anesthetized with chloralose. Recordings were obtained from single baroreceptor units as well as from the whole sinus nerve or a large strand of the nerve. Three observations are reported. First, in single units the pulsatile pressure threshold, which averaged 48 +/- 8 (SEM) mm Hg, was far below the static pressure threshold, which averaged 79 +/- 8 mm Hg (p less than 0.05, n = 15). Thus, pulsatility decreased the threshold by an average of 31 mm Hg in contrast to the minimal or lack of decrease in threshold reported by others in aortic baroreceptors. Second, at moderate arterial pressures a shift from static to pulsatile pressure caused a decrease in single and multiple unit activities. In single units, the decrease approximated 15% (from 42.0 +/- 2.1 to 35.5 +/- 1.9 spikes/sec, p less than 0.05, n = 25). In all units, there was no diastolic nerve activity ("silence") when diastolic pressure was 1 to 10 mm Hg above static pressure threshold; 80% of the units exhibited "diastolic silence" when diastolic pressure was 20-30 mm Hg above threshold and 40% of the units showed silence at diastolic pressures 40-50 mm Hg above threshold. In whole nerve recordings, pulsatility increased activity from 57 +/- 15 to 142 +/- 29 spikes/sec (p less than 0.05) at low mean arterial pressures (50 and 75 mm Hg), as expected from the reduction in pressure threshold noted in single units, and decreased activity by approximately 15% (from 373 +/- 69 to 320 +/- 55 spikes/sec, p less than 0.05, n = 9) at mean arterial pressures of 125 and 150 mm Hg. This decrease in activity with a shift from static to pulsatile pressure at moderate arterial pressures has not been reported previously. Third, the static pressure-activity curve was sigmoid, and its gain peaked sharply at 75-100 mm Hg; in contrast, the pulsatile pressure-activity curve was linear between 25 and 150 mm Hg, and its maximum gain was half the maximum gain during static pressure. These differences between the static pressure-activity curve and the pulsatile pressure-activity curve were noted during both increases and decreases in carotid sinus pressure; both curves exhibited some hysteresis during the decreases in pressure.
More Related Videos
09:56Implantation of Combined Telemetric ECG and Blood Pressure Transmitters to Determine Spontaneous Baroreflex Sensitivity in Conscious Mice
Published on: February 14, 2021
09:24O-Ring Aortic Banding Versus Traditional Transverse Aortic Constriction for Modeling Pressure Overload-Induced Cardiac Hypertrophy
Published on: October 6, 2022
Related Concept Videos
Sites for measuring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Measurement of Blood Pressure
Pulse
The pulse serves as a clinical indicator...
Autoregulation of Blood Flow
Chemical Signaling in Autoregulation
Chemical signaling operates at the precapillary sphincter level, inciting either contraction or relaxation.