Simple and cost-effective methods for precise analysis of trace element abundances in geological materials with
Shuo Chen1, Xiaohong Wang2, Yaoling Niu3
1Institute of Oceanology, Chinese Academy of Sciences, Qingdao 266071, China; Laboratory for Marine Geology, Qingdao National Laboratory for Marine Science and Technology, Qingdao 266061, China; University of Chinese Academy of Sciences, Beijing 100049, China.
Abstract:
Inductively coupled plasma mass spectrometry (ICP-MS) is the most commonly used technique to determine the abundances of trace elements in a wide range of geological materials. However, incomplete sample digestion, isobaric interferences and instrumental drift remain obvious problems that must be overcome in order to obtain precise and accurate results. For this reason, we have done many experiments and developed a set of simple, cost-effective and practical methods widely applicable for precise and rapid determination of trace element abundances in geological materials using ICP-MS. Commonly used high-pressure digestion technique is indeed effective in decomposing refractory phases, but this inevitably produces fluoride complexes that create new problems. We demonstrate that the fluoride complexes formed during high-pressure digestion can be readily re-dissolved using high-pressure vessel at 190°C for only 2h for 50mg sample. In the case of isobaric interferences, although oxide (e.g., MO+/M+) and hydroxide (e.g., MOH+/M+) productivity is variable between runs, the (MO+/M+)/(CeO+/Ce+) and (MOH+/M+)/(CeO+/Ce+) ratios remain constant, making isobaric interference correction for all other elements of interest straightforward, for which we provide an easy-to-use off-line procedure. We also show that mass-time-intensity drift curve is smooth as recognized previously, for which the correction can be readily done by analyzing a quality-control (QC) solution and using off-line Excel VBA procedure without internal standards. With these methods, we can produce data in reasonable agreement with recommended values of international rock reference standards with a relative error of <8% and precision generally better than 5%. Importantly, compared to the widely used analytical practice, we can effectively save >60% of time (e.g., <24h vs. >60h).
Related Concept Videos
Inductively Coupled Plasma–Mass Spectrometry (ICP–MS): Overview
Inductively Coupled Plasma-Mass Spectrometry (ICP-MS): Interferences
Inductively Coupled Plasma Atomic Emission Spectroscopy: Principle
The ions and electrons produced interact with the fluctuating magnetic field created by a water-cooled...
Atomic Emission Spectroscopy: Lab
Atomic Absorption Spectroscopy: Lab
Solutions containing organic solvents, such as low-molecular-mass alcohols, esters, or ketones, enhance absorbances by increasing...
Inductively Coupled Plasma Atomic Emission Spectroscopy: Instrumentation
There are three main types of inductively coupled plasma atomic emission spectroscopy (ICP-AES) instruments: sequential, simultaneous multichannel, and Fourier transform instruments, with the latter being less commonly used....