Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

Magnetic Resonance Imaging01:24

Magnetic Resonance Imaging

5.4K
Magnetic resonance imaging (MRI) is a noninvasive medical imaging technique based on a phenomenon of nuclear physics discovered in the 1930s, in which matter exposed to magnetic fields and radio waves was found to emit radio signals. In 1970, a physician and researcher named Raymond Damadian noticed that malignant (cancerous) tissue gave off different signals than normal body tissue. He applied for a patent for the first MRI scanning device in clinical use by the early 1980s. The early MRI...
5.4K
NMR Spectrometers: Radiofrequency Pulses and Pulse Sequences01:17

NMR Spectrometers: Radiofrequency Pulses and Pulse Sequences

876
A pulse is a short burst of radio waves distributed over a range of frequencies that simultaneously excites all the nuclei in the sample. Upon passing a radio frequency pulse along the x-axis, the nuclei absorb energy corresponding to their Larmor frequencies and achieve resonance. This shifts the net magnetization vector from the z-axis toward the transverse plane. This angle of rotation of the magnetization vector, or the flip angle, is proportional to the duration and intensity of the pulse.
876
Atomic Nuclei: Magnetic Resonance01:05

Atomic Nuclei: Magnetic Resonance

715
The number of nuclear spins aligned in the lower energy state is slightly greater than those in the higher energy state. In the presence of an external magnetic field, as the spins precess at the Larmor frequency, the excess population results in a net magnetization oriented along the z axis. When a pulse or a short burst of radio waves at the Larmor frequency is applied along the x axis, the coupling of frequencies causes resonance and flips the nuclear spins of the excess population from the...
715
Atomic Nuclei: Nuclear Relaxation Processes01:23

Atomic Nuclei: Nuclear Relaxation Processes

697
In the absence of an external magnetic field, nuclear spin states are degenerate and randomly oriented. When a magnetic field is applied, the spins begin to precess and orient themselves along (lower energy) or against (higher energy) the direction of the field. At equilibrium, a slight excess population of spins exists in the lower energy state. Because the direction of the magnetic field is fixed as the z-axis,  the precessing magnetic moments are randomly oriented around the z-axis.
697

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

An 80-channel receive array for 10.5T neuroimaging: Key considerations for SNR optimization.

bioRxiv : the preprint server for biology·2026
Same author

Mesoscale Whole-Brain T<sub>2</sub>*-Weighted and Associated Quantitative MRI in Humans at 10.5 T.

Magnetic resonance in medicine·2026
Same author

A Numerical Alternative to MR Thermometry for Safety Validation of Multi-Channel RF Transmit Coils.

Magnetic resonance in medicine·2026
Same author

Designing B<sub>1</sub>-Selective Pulses by Frequency Modulating in a Second Rotating Frame.

Magnetic resonance in medicine·2026
Same author

EM Simulation Model of a Clinically-Used RF Head Coil at 7 T.

Magnetic resonance in medicine·2026
Same author

Advancing whole-brain BOLD functional MRI in humans at 10.5 T with motion-robust 3D echo-planar imaging, parallel transmission, and high-density radiofrequency receive coils.

Magnetic resonance in medicine·2025
Same journal

Suppression of Oscillation and Ghosting in RF-Spoiled Gradient-Echo-Based Dynamic Imaging.

Magnetic resonance in medicine·2026
Same journal

A Simple, Dynamic Geometric Phantom for MRI and CT Reconstruction Pipelines: Beyond Shepp-Logan.

Magnetic resonance in medicine·2026
Same journal

7T 3D-EPI PCASL With High SNR Efficiency and Robustness to Through-Plane B<sub>0</sub> Field Gradients.

Magnetic resonance in medicine·2026
Same journal

A Comparison of Tissue Property Values Estimated Using Conventional Cardiac MRF and MT-Cardiac MRF.

Magnetic resonance in medicine·2026
Same journal

Dependence of the Extra-Cellular Diffusion Coefficient on the Fractions of Neurites and Cell Bodies in Gray Matter.

Magnetic resonance in medicine·2026
Same journal

Triple-Pulse <sup>23</sup>Na MRI Sequence (TriNa) for Simultaneous Acquisition of Spin-Density-Weighted and Fluid-Attenuated Images.

Magnetic resonance in medicine·2026
See all related articles

Related Experiment Video

Updated: Aug 13, 2025

Quantitative Magnetic Resonance Imaging of Skeletal Muscle Disease
09:30

Quantitative Magnetic Resonance Imaging of Skeletal Muscle Disease

Published on: December 18, 2016

19.6K

Fast spin-echo approach for accelerated B1 gradient-based MRI.

Taylor Froelich1, Lance DelaBarre1, Paul Wang1,2

  • 1Center for Magnetic Resonance Research and Department of Radiology, University of Minnesota, Minneapolis, Minnesota, USA.

Magnetic Resonance in Medicine
|January 20, 2023
PubMed
Summary
This summary is machine-generated.

This study introduces a multi-echo frequency-modulated Rabi-encoded echoes (FREE) technique for faster MRI scans. The enhanced FREE method accelerates image acquisition while maintaining image quality and contrast versatility.

Keywords:
B1-gradient encodingacceleratedfast spin echolow-cost MRIradiofrequency imagingsurface coil

More Related Videos

A Magnetic Resonance Imaging Protocol for Stroke Onset Time Estimation in Permanent Cerebral Ischemia
09:59

A Magnetic Resonance Imaging Protocol for Stroke Onset Time Estimation in Permanent Cerebral Ischemia

Published on: September 16, 2017

14.2K
Registered Bioimaging of Nanomaterials for Diagnostic and Therapeutic Monitoring
17:16

Registered Bioimaging of Nanomaterials for Diagnostic and Therapeutic Monitoring

Published on: December 9, 2010

10.4K

Related Experiment Videos

Last Updated: Aug 13, 2025

Quantitative Magnetic Resonance Imaging of Skeletal Muscle Disease
09:30

Quantitative Magnetic Resonance Imaging of Skeletal Muscle Disease

Published on: December 18, 2016

19.6K
A Magnetic Resonance Imaging Protocol for Stroke Onset Time Estimation in Permanent Cerebral Ischemia
09:59

A Magnetic Resonance Imaging Protocol for Stroke Onset Time Estimation in Permanent Cerebral Ischemia

Published on: September 16, 2017

14.2K
Registered Bioimaging of Nanomaterials for Diagnostic and Therapeutic Monitoring
17:16

Registered Bioimaging of Nanomaterials for Diagnostic and Therapeutic Monitoring

Published on: December 9, 2010

10.4K

Area of Science:

  • Magnetic Resonance Imaging (MRI)
  • Pulse Sequence Development
  • Medical Physics

Background:

  • Traditional MRI acquisition is time-consuming.
  • Frequency-modulated Rabi-encoded echoes (FREE) offers gradient-free spatial encoding.
  • Previous FREE implementations were limited by single-line k-space acquisition.

Purpose of the Study:

  • To develop an accelerated multi-echo FREE technique for faster MRI acquisition.
  • To expand the clinical feasibility of gradient-free MRI.
  • To enable multiple k-space lines collection within a single echo train.

Main Methods:

  • Developed a multi-echo acquisition scheme for FREE.
  • Utilized adiabatic full-passage pulses and spatially varying RF fields.
  • Performed theoretical analysis, computer simulations, and experimental validation on human visual cortex.

Main Results:

  • Achieved an acceleration factor of 3.9 without exceeding SAR limits.
  • Demonstrated acquisition of various contrasts, including inversion recovery.
  • Maintained the advantages of gradient-free encoding with enhanced speed.

Conclusions:

  • The multi-echo FREE technique significantly accelerates MRI acquisition.
  • This advancement improves the clinical viability of gradient-free imaging.
  • Further acceleration and advanced reconstruction can enhance FREE's clinical utility.