Related Experiment Video
Updated: Aug 13, 2025

Synthesis of Biocompatible Liquid Crystal Elastomer Foams as Cell Scaffolds for 3D Spatial Cell Cultures
Published on: April 11, 2017
In-Plane Impact Response of Graded Foam Concrete-Filled Auxetic Honeycombs
Xiaojuan Wang1, Kuncheng Jia1, Yan Liu2
1Key Laboratory of Urban Security and Disaster Engineering of Ministry of Education, Beijing University of Technology, Beijing 100124, China.
Abstract:
Foam-filled honeycombs have been widely applied due to their excellent load transfer mitigation and energy absorption capacity. In the present study, a layered graded foam concrete-filled auxetic honeycomb was proposed by tuning its overall compression deformation mode to layer-by-layer deformation mode to realize multi-level structural protection. The effect of the honeycomb cell-wall thickness gradient (with an average thickness of 0.25 mm, thickness gradients of 0.30:0.25:0.20, 0.35:0.25:0.15 and 0.40:0.25:0.10, and corresponding positive gradients) and the foam concrete filler density gradient (408:575:848, 848:575:408) on the response mode, load transfer, energy absorption, and Poisson's ratio of the proposed composite was systematically investigated. The results showed that the graded composite exhibited an obvious layered deformation mode and a negative Poisson's ratio effect under relatively low and moderate loading rates (1 m/s, 10 m/s, respectively), especially with the foam concrete density gradient. Under a high loading rate (100 m/s), the graded composite demonstrated progressive collapse initiating from the loading end with a layer-by-layer crushing mode, regardless of the thickness and density gradient. In the response of the composite with a 0.2:0.2:0.2 thickness ratio and a 408:575:848 foam concrete gradient subjected to 1 m/s crushing, the first-layer, second-layer, and third-layer foam concrete absorbed 94.62%, 88.72%, and 86.94% of the total foam concrete energy absorption in the corresponding crushing stage, respectively. Compared with the counterpart homogeneous composites, although the graded composite had an insignificant improvement on energy absorption (less than 5%), it was able to significantly reduce the peak load (as high as 30%) to mitigate the load transfer to the protected structure. The effective Poisson's ratio of the first layer in the composite with positive gradient (408:575:848) increased to -2 then converged to -0.6 under 2 m/s and 10 m/s crushing, and ranged from -0.4 to -0.1 under 50 m/s and 100 m/s crushing, respectively. The effective Poisson's ratio of the middle and bottom layers increased to -2 initially and converged to range -0.4 to -0.1, regardless of the crushing speed. The staged response mode of the graded composite facilitated the realization of multi-level structure protection with significantly reduced peak load transferred to the protected structure and tuned energy absorption.
More Related Videos
07:15A Testing Platform for Durability Studies of Polymers and Fiber-reinforced Polymer Composites under Concurrent Hygrothermo-mechanical Stimuli
Published on: December 11, 2014
09:54Author Spotlight: Enhancing Fiber Composite Laminate Quality with the Wet Hand Lay-Up/Vacuum Bag Process
Published on: June 30, 2023
Related Concept Videos
Behavior of Concrete Under Compressive Load
As the concrete specimen fractures under...
Impact Strength of Concrete
Dynamic Modulus of Elasticity of Concrete
The sonic test is a common method to determine the dynamic modulus. In this test, a concrete beam, sized either 6 x 6 x 30 inches or 4 x 4 x 20 inches, is clamped at its center. Vibrations are initiated at one end of the beam by an electromagnetic exciter unit powered by...
Elasticity in Concrete
Fiber Reinforced Concrete
Effects of Air-entrainment in Concrete