Related Experiment Video
Updated: Aug 13, 2025

Installation Method to Enhance Quality Control for Fiber Reinforced Polymer Spike Anchors
Published on: April 10, 2018
Computer Simulations of End-Tapering Anchorages of EBR FRP-Strengthened Prestressed Concrete Slabs at Service
Chirawat Wattanapanich1, Thanongsak Imjai1, Reyes Garcia2
1School of Engineering and Technology, Walailak University, Nakhon Si Thammarat 80161, Thailand.
Abstract:
This article examines numerically the behavior of prestressed reinforced concrete slabs strengthened with externally bonded reinforcement (EBR) consisting of fiber-reinforced polymer (FRP) sheets. The non-linear finite element (FE) program Abaqus® is used to model EBR FRP-strengthened prestressed concrete slabs tested previously in four-point bending. After the calibration of the computational models, a parametric study is then conducted to assess the influence of the FRP axial stiffness (thickness and modulus of elasticity) on the interfacial normal and shear stresses. The numerical analysis results show that increasing the thickness or the elastic modulus of the FRP strengthening affects the efficiency of the FRP bonding and makes it susceptible to earlier debonding failures. A tapering technique is proposed in wet lay-up applications since multiple FRP layers are often required. It is shown that by gradually decreasing the thickness of the FRP strengthening, the concentration of stress along the plate end can be reduced, and thus, the overall strengthening performance is maximized. The tapering is successful in reducing the bond stress concentrations by up to 15%, which can be sufficient to prevent concrete rip-off and peel-off debonding failure modes. This article contributes towards a better understanding of the debonding phenomena in FRP-strengthened elements in flexure and towards the development of more efficient computational tools to analyze such structures.
More Related Videos
05:26Determination of the Mechanical Properties of Flexible Connectors for Use in Insulated Concrete Wall Panels
Published on: October 19, 2022
07:15A Testing Platform for Durability Studies of Polymers and Fiber-reinforced Polymer Composites under Concurrent Hygrothermo-mechanical Stimuli
Published on: December 11, 2014
Related Concept Videos
Dynamic Modulus of Elasticity of Concrete
The sonic test is a common method to determine the dynamic modulus. In this test, a concrete beam, sized either 6 x 6 x 30 inches or 4 x 4 x 20 inches, is clamped at its center. Vibrations are initiated at one end of the beam by an electromagnetic exciter unit powered by...
Prestressed Concrete
Fatigue Strength of Concrete
Behavior of Concrete Under Compressive Load
As the concrete specimen fractures under...
Tensile Strength Considerations of Concrete
The dimensions and shape of a concrete specimen...
Fiber Reinforced Concrete