Introduction:
The sample matrix composition, which is greatly affected by the type of blood collection tube used during phlebotomy, is of major importance in laboratory testing as it can influence test results. We developed an LC-MRM-MS test to molecularly characterize antithrombin in citrate plasma. The test principle differs greatly from traditional laboratory tests and the influence of varying plasma sample matrices is largely unknown.
Objectives:
To identify whether variations in sample matrix affect the LC-MRM-MS test for antithrombin and assess whether sample pre-processing by immunocapture reduces matrix-specific effects.
Methods:
Samples (n = 45) originating from four different blood collection tubes (sodium citrate, lithium heparin, K2-EDTA and K2-EDTA with protease inhibitors) were processed directly or after immunocapture. Antithrombin was digested into proteotypic peptides, which were monitored by LC-MRM-MS. Results from lithium heparin and the K2-EDTA matrices were compared to the standard sample matrix, sodium citrate, using Deming regression analysis and repeated measures one-way ANOVA.
Results:
Deming regression analysis of directly processed samples revealed slopes deviating >5% from the line of identity for at least six out of 22 peptides in all matrices. Significant differences between all matrices were found upon analysis by ANOVA for at least 10 peptides. Pre-processing by immunocapture led to slopes within 5% of the line of identity for nearly all peptides of the matrices. Furthermore, significant differences between matrices after immunocapture were only observed for four peptides.
Conclusion:
Variations in the sample matrix affect the measurement of antithrombin by LC-MRM-MS, but observed effects are greatly reduced upon pre-processing by immunocapture.
More Related Videos
09:49Investigation of Microbial Cooperation via Imaging Mass Spectrometry Analysis of Bacterial Colonies Grown on Agar and in Tissue During Infection
Published on: November 18, 2022
09:38Dithranol as a Matrix for Matrix Assisted Laser Desorption/Ionization Imaging on a Fourier Transform Ion Cyclotron Resonance Mass Spectrometer
Published on: November 26, 2013
Related Concept Videos
Matrix-Assisted Laser Desorption Ionization (MALDI)
The analyte of interest, a biomolecule or a mixture of biomolecules, is mixed with a suitable matrix material. The...
Immunoprecipitation
Chromatin Immunoprecipitation
Chromatin immunoprecipitation, also known as ChIP, is used to study protein-DNA or...
Inductively Coupled Plasma-Mass Spectrometry (ICP-MS): Interferences