Related Experiment Video
Updated: Aug 12, 2025

Multiplexed Fluorescent Immunohistochemical Staining of Four Endometrial Immune Cell Types in Recurrent Miscarriage
Published on: August 4, 2021
Validation of a multiple marker test for early pregnancy outcome prediction
Kassie J Bollig1, Suneeta Senapati2, Mary D Sammel3
1Department of Obstetrics and Gynecology, University of Pennsylvania, 3701 Market Street Suite 800, Philadelphia, PA, 19104, USA. kassie.bollig@pennmedicine.upenn.edu.
Purpose:
To validate the use of a multiple biomarker test panel for predicting first trimester pregnancy outcome in a multi-center cohort.
Methods:
A case-control study of women presenting with pain and bleeding in early pregnancy at 5-10 weeks gestational age was performed at three academic centers. Sera from women with ectopic pregnancy (EP), viable intrauterine pregnancy (IUP), and miscarriage (SAB) were analyzed via immunoassay for Activin A (AA), Progesterone (P4), A Disintegrin And Metalloprotease-12 (ADAM12), pregnancy-associated plasma protein A (PAPP-A), glycodelin (Glyc), and human chorionic gonadotropin (hCG). Biomarkers were assessed for reproducibility using medians, ranges, standard deviations, and area under receiver-operating characteristic curve (AUC) and accuracy in early pregnancy outcome classification compared to a previous derivation population.
Results:
In 192 pregnancies, the biomarkers demonstrated good reproducibility with similar medians, ranges, and AUCs when compared to the derivation population except glycodelin. Pregnancy location was conclusively classified in 53% (n = 94) of the whole study sample with 78% accuracy. Pregnancy viability was conclusively classified in 58% (n = 112) of the new sample with 89% accuracy. Results were similar with subsequent model revisions where glycodelin was excluded and in the subgroups of subjects with a hCG below 2000 mIU/mL and a gestational age less than 6 weeks.
Conclusion:
The use of a panel of biomarkers to maximize test accuracy of a prediction of pregnancy location and prediction of pregnancy viability was reproducible and validated in an external population from which it was derived, but clinical utility is limited based on the test characteristics obtained.
Related Concept Videos
Sign Test for Matched Pairs
To conduct the sign test, we first calculate the differences in...
Multiple Comparison Tests
It would be easy to compare two samples using a significance alpha level of 0.05. In other words, there is only one sample pair to be compared. However, it would be difficult to identify a significantly different sample if the number...