Aims:
Computer-assisted auscultation has become available to assist clinicians with physical examinations to detect congenital heart disease (CHD). However, its accuracy and effectiveness remain to be evaluated. This study seeks to evaluate the accuracy of auscultations of abnormal heart sounds of an artificial intelligence-assisted auscultation (AI-AA) platform we create.
Methods And Results:
Initially, 1397 patients with CHD were enrolled in the study. The samples of their heart sounds were recorded and uploaded to the platform using a digital stethoscope. By the platform, both remote auscultation by a team of experienced cardiologists from Shanghai Children's Medical Center and automatic auscultation of the heart sound samples were conducted. Samples of 35 patients were deemed unsuitable for the analysis; therefore, the remaining samples from 1362 patients (mean age-2.4 ± 3.1 years and 46% female) were analysed. Sensitivity, specificity, and accuracy were calculated for remote auscultation compared to experts' face-to-face auscultation and for artificial intelligence automatic auscultation compared to experts' face-to-face auscultation. Kappa coefficients were measured. Compared to face-to-face auscultation, remote auscultation detected abnormal heart sound with 98% sensitivity, 91% specificity, 97% accuracy, and kappa coefficient 0.87. AI-AA demonstrated 97% sensitivity, 89% specificity, 96% accuracy, and kappa coefficient 0.84.
Conclusions:
The remote auscultations and automatic auscultations, using the AI-AA platform, reported high auscultation accuracy in detecting abnormal heart sound and showed excellent concordance to experts' face-to-face auscultation. Hence, the platform may provide a feasible way to screen and detect CHD.
Related Concept Videos
Assessment of the Cardiovascular System IV: Auscultation
Normal Heart Sounds
S1 (First Heart Sound)-
S1 is made by the closure of the mitral and tricuspid valves (atrioventricular valves), marking the beginning of systole.
S2 (Second Heart Sound)-
S2 is made by the closure of the aortic and pulmonic valves (semilunar valves), marking the end of the systole.
Assessment of apical pulse
Assessing the apical pulse is a critical nursing procedure, particularly indicated for:
Cardiovascular System Abnormal Findings II: Auscultation
Abnormal Heart Sounds
Gallops:
Heart Sounds
Auscultation is the process of listening to these internal body sounds using a stethoscope. The heart produces four types of sounds, but only two—S1 and S2—can usually be heard with a stethoscope.
S1, also known as the "lub" sound, is caused by the closure of atrioventricular (A-V)...
Respiratory System Abnormal Finding II: Palpation and Auscultation
Palpation Findings
During a respiratory assessment, palpation can reveal several vital abnormalities:
Assessment of the Abdomen I: Inspection and Auscultation
The abdominal examination is a cornerstone of clinical medicine, serving as a critical tool in diagnosing various gastrointestinal (GI) diseases. It involves a systematic approach that includes inspection and auscultation, each with distinct yet complementary roles in assessing the abdomen. This article will delve into these two primary methods healthcare professionals use to examine the abdomen.
Inspection of the Abdomen
The first step in any abdominal examination is inspection....