Accuracy of residual respiratory event detection by CPAPs: a meta-analysis
Imran H Iftikhar1,2, Ahmed BaHammam3,4, Haitham Jahrami5,6
1Department of Medicine, Division of Pulmonary, Allergy, Critical Care & Sleep Medicine, Emory University School of Medicine, 613 Michael St., Atlanta, GA, USA. imran.hasan.iftikhar@emory.edu.
Purpose:
Most continuous positive airway pressure (CPAP) machines have built-in manufacturer-specific proprietary algorithms for automatic respiratory event detection (AED) based on very specific respiratory events scoring criteria. With regards to the accuracy of these data from CPAP machines, evidence from the literature seems conflicting, which formed the basis for this meta-analysis.
Methods:
A meta-analysis was performed on studies that reported Bland-Altman analysis data on agreement (mean bias and limits of agreement [LoA]) of CPAP-determined apnea-hypopnea index (AHI) at therapeutic pressures (AHIFLOW) with that determined from simultaneously conducted polysomnograms (AHIPSG).
Results:
In six studies, ResMed CPAPs were used, and in another six studies, Respironics CPAPs were used, while only one study used Fisher & Paykel (F&P) CPAPs. The pooled mean AHI bias from ResMed CPAP studies was - 1.01 with pooled LoAs from - 3.55 to 1.54 (I2 = 17.5%), and from Respironics CPAP studies, pooled mean AHI bias was - 0.59 with pooled LoAs from - 3.22 to 2.05 (I2 = 0%). Pooled percentage errors (corresponding to LoAs) from four ResMed CPAP studies, four Respironics CPAP studies, and the F&P CPAP study were 73%, 59%, and 112%, respectively. A review of the literature for this meta-analysis also revealed lack of uniformity not only in the CPAP manufacturers' respiratory events scoring criteria but also in that used for PSGs across the studies analyzed.
Conclusions:
Even though the pooled results of mean AHI bias suggest good clinical agreement between AHIPSG and AHIFLOW, percentage errors calculated in this meta-analysis indicate the possibility of a significant degree of imprecision in the estimation of AHIFLOW by CPAP machines.
More Related Videos
Related Concept Videos
Assessment of Ventilation I: Respiratory Rate
A Ventilation assessment is critical for monitoring a patient's health status. Respiration, one of the most accessible vital signs, provides insights into the function of numerous body systems and can indicate serious health issues, such as brainstem injuries from head trauma.
Critical Guidelines for Assessing Ventilation:
Respiratory Assessment: Purpose and Indications
Objectives and Importance:
The primary goal of respiratory assessment is to evaluate patients at early risk of clinical deterioration. Since respiratory distress often precedes other signs of declining health, breathing patterns and sounds become a...
Assessment of Ventilation II: Respiratory Depth and Rhythm
Respiratory depth measures the volume of air inhaled or exhaled during a breath. It can vary from shallow to deep and typically remains consistent when a person is at rest or asleep. Occasionally, individuals will automatically inhale deeply, known as sighing, which inflates the lungs with more air than normal breathing.
To assess respiratory depth, observe the degree of chest excursion or movement:
Mechanical Ventilation III: Noninvasive Ventilation
Noninvasive Positive-Pressure Ventilation...
Respiratory System Abnormal Finding I: Inspection and Percussion
Inspection Findings
During an inspection, several findings may suggest the presence of respiratory distress or disease. Pursed-lip breathing, where exhalation is slowed by...
Physical Assessment of the Respiratory Tract II: Inspection
Chest Configuration
The chest configuration...