Purpose:
This study aimed to compare the performance of 68Ga-FAPI and 18F-FDG PET/CT in the evaluation of patients with newly diagnosed breast cancer.
Methods:
Thirty-four women with newly diagnosed breast cancer who underwent both 68Ga-FAPI and 18F-FDG PET/CT within 1 week were prospectively included in the study. The imaging characteristics of primary lesions, diagnostic efficiency of lymph node metastasis (LNM), and accuracy of N stage evaluation between 2 PET/CTs were compared.
Results:
68Ga-FAPI showed higher SUVmax (11.06 ± 5.48 vs 8.33 ± 6.07, P = 0.02) and tumor-to-background ratio (15.32 ± 10.33 vs 8.25 ± 5.51, P < 0.001) than 18F-FDG in primary tumors. 68Ga-FAPI SUVmax was positively correlated with the pathological grade of the primary lesions and the final stage of the patients (P < 0.001). The specificity and accuracy of 68Ga-FAPI was higher than that of 18F-FDG in the diagnosis of LNMs on patient-based and lesion-based analysis (P < 0.001). The accuracy for the evaluation of N stage and N0 axillar status was 91.2% (31/34) and 85.7% (12/14) for 68Ga-FAPI, and 73.5% (25/34) and 42.9% (6/14) for 18F-FDG, respectively.
Conclusions:
The 68Ga-FAPI SUVmax was positively correlated with the pathological grade of the primary lesions and the final stage of the patients. 68Ga-FAPI PET/CT has higher accuracy than 18F-FDG in the evaluation of N stage, especially N0 axillar status, which is helpful to improve the treatment strategy for breast cancer patients.
Related Concept Videos
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body...
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
![An Automated Radiosynthesis of [68Ga]Ga-FAPI-46 for Routine Clinical Use](/_next/image?url=https%3A%2F%2Fcloudfront.jove.com%2FCDNSource%2Fteasers%2F66708.jpg&w=3840&q=50)
![Automated Preparation of [68Ga]Ga-3BP-3940 on a Synthesis Module for PET Imaging of the Tumor Microenvironment](/_next/image?url=https%3A%2F%2Fcloudfront.jove.com%2FCDNSource%2Fteasers%2F68356.jpg&w=3840&q=50)