Can We Make Blood Flow Restriction Training More Accessible? Validity of a Low-Cost Blood Flow Restriction Device to
Martin Keller1, Oliver Faude1, Albert Gollhofer2
1Department of Sport, Exercise and Health, University of Basel, Basel, Switzerland.
Abstract:
Keller, M, Faude, O, Gollhofer, A, and Centner, C. Can we make blood flow restriction training more accessible? Validity of a low-cost blood flow restriction device to estimate arterial occlusion pressure. J Strength Cond Res 37(8): 1581-1587, 2023-Evidence indicates that low-load resistance training with blood flow restriction (BFR) results in comparable gains in muscle mass and muscle strength as high-load resistance training without BFR. Low-load BFR training is a promising tool for areas such as rehabilitation because individuals are exposed to low mechanical stress. However, BFR training is only safe and effective when the cuff pressure is individually adjusted to the arterial occlusion pressure (AOP). Generally, thresholds for AOP are typically determined with sophisticated laboratory material, including Doppler ultrasound and tourniquet systems. Therefore, this study investigated the validity of a low-cost BFR product with automatic AOP assessment (AirBands International) compared with the gold standard for determining the individual AOP. Valid measurements were obtained at the arms and legs in 104 healthy volunteers. For the arms ( n = 49), a Bland-Altman analysis revealed a mean difference of 7 ± 13 mm Hg between the 2 methods, with slightly higher pressure levels for the gold standard (131 ± 14 mm Hg) than for the low-cost device (125 ± 17 mm Hg). For the legs ( n = 55), the low-cost device reached its maximum pressure capacity in 70% of subjects during AOP identification, making the results on the legs unreliable. Although the low-cost device is a valid tool for identifying the individual AOP in the arms, the device cannot be recommended for use at the legs because of its limited pressure capacity. When using the low-cost device for BFR training at the arms, it is recommended to apply the cuff pressure to 60% of the individual AOP to meet current BFR training guidelines.
More Related Videos
Related Concept Videos
Sites for measruring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement
Pre-Procedural Guidelines for Assessing Blood Pressure
Assessment of blood pressure in brachial artery(one-step method)
Prepare for the Procedure:
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Assessment of blood pressure in brachial artery(two-step method)
Peripheral Arterial Disease II: Clinical Manifestations and Diagnostic Evaluation