Application of post-column reaction gas chromatography with a single reference gas for offshore air and gas seeped
Yuko Kitamaki1, Nobuyuki Aoki2, Shinsuke Aoki3
1National Metrology Institute of Japan (NMIJ), National Institute of Advanced Industrial Science and Technology (AIST), 1-1-1 Umezono, Tsukuba, Ibaraki, 305-8563, Japan. y-kitamaki@aist.go.jp.
Abstract:
Ambient air commonly contains carbon dioxide at concentrations greater than 400 µmol mol-1 and methane at ~ 2000 nmol mol-1; non-methane hydrocarbons are also widespread in the atmosphere at much lower concentrations. For quantification of various carbon-containing compounds in typical analytical instrument, corresponding number of reference materials are required. Therefore, the development of a method that uses a single reference material applicable to air monitoring is desired. Here, we examined a post-column reaction system combined with a gas chromatograph equipped with a flame ionization detector (FID), which involves oxidation and reduction processes after separation. To determine various carbon-containing gases by post-column reaction gas chromatography with FID (GC-r-FID) using a single reference, it is necessary to confirm a good linearity of the response with carbon concentrations originating from various carbon-containing gases. When mixtures of carbon-containing gases at three different concentrations and the calibration curve of the FID response with the concentration converted into methane were used, a single linear calibration curve (correlation coefficient > 0.9999, 18 points) was obtained over four orders of magnitudes (to ~ 5000 µmol mol-1 as methane). The applicability of GC-r-FID was confirmed by determining carbon-containing gases in air and gas seeped from the seafloor samples. Because the results were comparable to those obtained by conventional GC-FID and GC-thermal conductivity detector, typically GC-r-FID with a single reference gas should be suitable for air monitoring.
More Related Videos
08:37Measurement of H2S in Crude Oil and Crude Oil Headspace Using Multidimensional Gas Chromatography, Deans Switching and Sulfur-selective Detection
Published on: December 10, 2015
07:49On-line Analysis of Nitrogen Containing Compounds in Complex Hydrocarbon Matrixes
Published on: August 5, 2016
Related Concept Videos
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a...
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall....
Gas Chromatography: Sample Injection Systems
Two primary injection methods are used...
Gas Chromatography: Types of Columns and Stationary Phases
For an analyte to remain on the column for a sufficient amount of time, it must exhibit some level of compatibility (or...
Gas Chromatography: Types of Detectors-II
Gas Chromatography: Overview of Detectors
A non-destructive detector allows a sample to be analyzed without altering or consuming it, meaning the sample can be collected after detection for further analysis. Examples include thermal conductivity detectors and...