Purpose:
The purpose of this study was to introduce a new method of limbal stem cell transplantation using autologous platelet-rich plasma (E-PRP) eye drops for unilateral total limbal stem cell deficiency.
Methods:
Patients with total unilateral limbal stem cell deficiency due to chemical burn underwent mini-conjunctival limbal autograft using autologous E-PRP drops. One small limbal block, measuring 2 × 2 mm, was harvested from the patients' contralateral healthy eye and transplanted to the diseased eye. All patients received E-PRP drops until achieving complete corneal epithelialization. Subsequent corneal transplantation was performed in eyes with significant stromal opacification. Corneal buttons obtained during corneal transplantation underwent immunohistochemistry for the evaluation of limbal stem cell markers (ABCG2 and P63). Visual acuity, epithelial healing, corneal clarity, and regression of corneal conjunctivalization/vascularization were evaluated after surgery.
Results:
Ten patients with acid (n = 7) or alkali (n = 3) burn were included. The mean follow-up period was 21.7 ± 5.8 months (range, 12-32 months). Corneas were completely reepithelialized within 14.9 ± 3.5 days (range, 11-21 days). Corneal conjunctivalization/vascularization dramatically regressed 1 to 2 months after surgery in all cases, and corneal clarity considerably improved in 7 patients. In the 3 eyes with significant stromal opacification, subsequent optical penetrating keratoplasty was performed. The ocular surface was stable throughout the follow-up period in all eyes. BSCVA improved to 0.60 ± 0.0.32 and 0.46 ± 0.0.25 logMAR in eyes with and without corneal transplantation, respectively, at the final follow-up visit. ABCG2 and P63 markers were detected on corneal buttons after keratoplasty.
Conclusions:
Based on our clinical and laboratory findings, mini-conjunctival limbal autograft using E-PRP can be considered as a promising alternative to ocular surface reconstruction.