Related Experiment Video
Updated: Aug 11, 2025

Software for Analysis of Heart Rate and Blood Pressure Time-series Data from the Valsalva Maneuver
Published on: June 27, 2025
Blood pressure estimation by spatial pulse-wave dynamics in a facial video
Kaito Iuchi1,2, Ryogo Miyazaki1,2, George C Cardoso3
1Graduate School of Science and Engineering, Department of Imaging Science, Chiba University, Japan.
Abstract:
We propose a remote method to estimate continuous blood pressure (BP) based on spatial information of a pulse-wave as a function of time. By setting regions of interest to cover a face in a mutually exclusive and collectively exhaustive manner, RGB facial video is converted into a spatial pulse-wave signal. The spatial pulse-wave signal is converted into spatial signals of contours of each segmented pulse beat and relationships of each segmented pulse beat. The spatial signal is represented as a time-continuous value based on a representation of a pulse contour in a time axis and a phase axis and an interpolation along with the time axis. A relationship between the spatial signals and BP is modeled by a convolutional neural network. A dataset was built to demonstrate the effectiveness of the proposed method. The dataset consists of continuous BP and facial RGB videos of ten healthy volunteers. The results show an adequate estimation of the performance of the proposed method when compared to the ground truth in mean BP, in both the correlation coefficient (0.85) and mean absolute error (5.4 mmHg). For comparison, the dataset was processed using conventional pulse features, and the estimation error produced by our method was significantly lower. To visualize the root source of the BP signals used by our method, we have visualized spatial-wise and channel-wise contributions to the estimation by the deep learning model. The result suggests the spatial-wise contribution pattern depends on the blood pressure, while the pattern of pulse contour-wise contribution pattern reflects the relationship between percussion wave and dicrotic wave.
Related Concept Videos
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Measurement of Blood Pressure
Pre-Procedural Guidelines for Assessing Blood Pressure
Sites for measruring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement
Assessment of blood pressure in brachial artery(two-step method)

