Related Experiment Video
Updated: Aug 11, 2025

The Application of 1% Methylene Blue Dye As a Single Technique in Breast Cancer Sentinel Node Biopsy
Published on: June 1, 2019
Reducing workload in malignant melanoma sentinel node examination: a national study of pathology reports from 507
Carina Mellemgaard1,2, Ib Jarle Christensen3, Giedrius Salkus4
1Department of Pathology, Aarhus University Hospital, Aarhus, Denmark carinamellemgaard@outlook.dk.
Aims:
Even though extensive melanoma sentinel node (SN) pathology protocols increase metastasis detection, there is a need for balancing high detection rates with reasonable workload. A newly tested Danish protocol recommended examining nodes at six levels 150 µm apart (six-level model) and using SOX10 and Melan-A immunohistochemistry (IHC). We explored if a protocol examining 3 levels 300 µm apart (three-level model) combined with IHC would compromise metastasis detection. The study aim was to optimise the protocol to reduce workload without compromising detection rate.
Methods:
8 months after protocol implementation, we reviewed the pathology reports of SNs from 507 melanoma patients nationwide, including 117 SN-positive patients. Each report was reviewed to determine histopathological features, including detection of metastasis, exact levels with metastasis, exact levels with metastasis >1 mm in diameter and IHC results.
Results:
The six-level model detected metastases in 23% of patients, whereas the three-level model would have detected metastases in 22% of patients. The three-level model would have missed a few small metastases (n=4), measuring <0.1 mm, 0.1 mm, 0.4 mm and 0.1 mm, respectively. The six-level model detected metastases >1 mm in 7% of patients. One of these metastases (measuring 1.1 mm) would have been detected by the three-level model, but not as >1 mm. SOX10 and Melan-A had equal sensitivity.
Conclusions:
Reducing the number of levels examined to three levels 300 µm apart combined with IHC does not have significant impact on metastasis detection rate, and we will therefore recommend that the future melanoma SN guideline takes this into consideration to reduce overall workload.
More Related Videos
09:38Minimally Invasive Isolated Limb Perfusion (MI-ILP) for Locally Advanced Melanomas and Sarcomas of the Extremity
Published on: January 31, 2025
08:18Analysis of Lymph Node Volume by Ultra-High-Frequency Ultrasound Imaging in the Braf/Pten Genetically Engineered Mouse Model of Melanoma
Published on: September 8, 2021