Related Experiment Video
Updated: Aug 11, 2025

IridiumIII Luminescent Probe for Detection of the Malarial Protein Biomarker Histidine Rich Protein-II
Published on: July 7, 2015
Hg(II) immobilization and detection using gel formation with tetra-(4-pyridylphenyl)ethylene and an
Bing Hu1, Taibao Wei2, Yanjun Cui3
1College of Science, Gansu Agricultural University, Lanzhou, 730070, Gansu, People's Republic of China. bb810410@aliyun.com.
Abstract:
Tetra-(4-pyridylphenyl)ethylene (TPPE), featuring an aggregation-induced luminescence effect (AIE), has been synthesized and used for selective detection of Hg2+ in DMF/H2O (3:7, v/v) binary solutions. There was a color change from colorless to yellow in the detection of the Hg2+ ions, in addition to an increased fluorescence emission. This shows that TPPE will function as an excellent "turn-on" fluorescence probe in the detection Hg2+. Moreover, the interference of Al3+, Ba2+, Mn2+, Ca2+, Fe3+, Cu2+, Ag+, Cd2+, Co2+, Ni2+, Mg2+, Pb2+, Zn2+, and Cr3+ ions was found to be negligible under optimized solvent conditions. Cysteine and EDTA were also found to form TPPE-based fluorescent switches with the Hg2+ ions. The practical use of the TPPE sensor was also demonstrated by using a specific test kit. Characterization using FT-IR, NMR titration, UV titration, EDS, and HR-MS techniques showed that Hg2+ will form a 1:1 complex with TPPE. Also, the observation of a Tyndall effect, in addition to UV absorption and fluorescence spectra, did clearly demonstrate the presence of an AIE. More noteworthy, TPPE and Hg2+ were found to form a metal-organic gel (MOG) in the DMF solution. The SEM, TEM, ICP, and Zeta potential analyses confirmed that the fluorescent MOG could further adsorb an excess of Hg2+ ions. The BET analyses revealed that the MOG showed a type IV-H3 hysteresis loop according to the International Union of Pure and Applied Chemistry classification. The results of the XRD analysis and of the spectroscopic titrations show that a π-π stacking may be the auxiliary driving force for the gel formation, after that a coordination has taken place. These results indicate that further research on structurally simple metal ion fluorescent probes, which are based on the AIE, is promising for the achievement of a simultaneous fluorescent detection and adsorption of heavy metal pollutants.
Related Concept Videos
Photoluminescence: Applications
Labeling DNA Probes
Radioisotopes, fluorophores, or small molecule binding partners like biotin or digoxigenin, are the most widely used reporter tags for labeling DNA probes. These labels can be attached to the probe DNA molecule via...

