Related Experiment Video
Updated: Aug 11, 2025

A Microfluidic-based Electrochemical Biochip for Label-free DNA Hybridization Analysis
Published on: September 10, 2014
Light-Amplified CISS-Based Hybrid QD-DNA Impedimetric Device for DNA Hybridization Detection
Prashant K Bhartiya1, Suryansh1, Neeraj Bangruwa1
1Department of Physics & Astrophysics, University of Delhi, New Delhi 110007, India.
Abstract:
We design and build a novel light-amplified electrochemical impedimetric device based on the CISS effect to detect DNA hybridization using a hybrid quantum dot (QD)-DNA monolayer on a ferromagnetic (FM) Ni/Au thin film for the first time. Using spin as a detection tool, the current research considers the chiral-induced spin selectivity (CISS) phenomenon. After injecting a spin current into the QD-DNA system with opposite polarities (up and down), the impedimetric device revealed a large differential change in the charge-transfer resistance (ΔRct) of ∼100 ohms for both spins. Nearly, a threefold increase in the ΔRct value to ∼270 ohms is observed when light with a wavelength of 532 nm is illuminated on the sample, owing to the amplified CISS effect. The yield of spin polarization as extracted from the Nyquist plot increases by a factor of more than 2 when exposed to light, going from 6% in the dark to 13% in the light. The impact of light on the CISS effect was further corroborated by the observation of the spin-dependent asymmetric quenching of photoluminescence (PL) in the same hybrid system. These observations are absent in the case of a noncomplementary QD-DNA system due to the absence of a helical structure in DNA. Based on this, we develop a spin-based DNA hybridization sensor and achieve a limit of detection of 10 fM. These findings open a practical path for the development of spin-based next-generation impedimetric DNA sensors and point-of-care devices.
More Related Videos
07:16Author Spotlight: Advancements in DNA Nanosensors – Addressing Sensitivity and Selectivity Challenges in Molecular Detection
Published on: February 9, 2024
08:23Single Droplet Digital Polymerase Chain Reaction for Comprehensive and Simultaneous Detection of Mutations in Hotspot Regions
Published on: September 25, 2018
Related Concept Videos
Labeling DNA Probes
Radioisotopes, fluorophores, or small molecule binding partners like biotin or digoxigenin, are the most widely used reporter tags for labeling DNA probes. These labels can be attached to the probe DNA molecule via...
FISH - Fluorescent In-situ Hybridization
Southern Blot
Denatured DNA fragments must be transferred onto a carrier membrane from the gel to make it accessible to a probe - a small ssDNA fragment complementary to the target DNA...