Related Experiment Video
Updated: Aug 11, 2025

Separation of Uranium and Thorium for 230Th-U Dating of Submarine Hydrothermal Sulfides
Published on: May 20, 2019
Fast and selective reversed-phase high performance liquid chromatographic separation of UO2 2+ and Th4+ ions using
Aswanidevi Kongasseri1, Thirumalai Madhesan1, Suchashrita Mitra1
1Department of Chemistry, School of Advanced Sciences, Vellore Institute of Technology (VIT) Vellore Tamil Nadu 632014 India akhila.maheswari@vit.ac.in prabhakaran.d@vit.ac.in +91-9600061952.
Abstract:
Reprocessing nuclear-spent fuels is highly demanded for enhanced resource efficacy and removal of the associated radiotoxicity. The present work elucidates the rapid separation of UO2 2+ and Th4+ ions using a reversed-phase high-performance liquid chromatographic (RP-HPLC) technique by dynamically modifying the surface of a C18 silica monolith column with target-specific ionophoric ligands. For the dynamic modification, four analogous aromatic amide ligands, N 1,N 1,N 3,N 3,N 5,N 5-hexa(alkyl)benzene-1,3,5-tricarboxamide (alkyl = butyl, hexyl, octyl, and decyl) as column modifiers were synthesized. The complexation properties and retention profiles of the amide-based column modifiers for the selective and sequential separation of UO2 2+ and Th4+ ions were investigated. In addition, the selective separation of UO2 2+ and Th4+ ions among the competitive ions of similar chemical properties were also studied. The ionophore immobilized C18 silica monolith columns demonstrated a varying degree of retention behavior for UO2 2+ and Th4+ ions (UO2 2+ is retained longer than Th4+ under all analytical conditions), eventually leading to rapid separations within a period of ≤5 min. A 0.1 M solution of 2-hydroxyisobutyric acid (HIBA, 1 mL min-1) served as the mobile phase, and the qualitative and quantitative assessment of the sequentially separated 5f metal ions was achieved through post-column derivatization reaction, using arsenazo(iii) as a post-column reagent (PCR; 1.5 mL min-1) prior to analysis using a UV-vis detector, at 665 nm (λ max). The developed technique was further evaluated by standardizing various analytical parameters, including modifier concentration, mobile phase pH, mobile phase flow rate, etc., to yield the best chromatographic separation. Also, the conceptual role of alkyl chain length (in the modifier) on the retention behavior of the studied metal ions was evaluated for cutting-edge future applications.
Related Concept Videos
High-Performance Liquid Chromatography: Introduction
In HPLC, two phases play a critical role in the separation process:
High-Performance Liquid Chromatography: Elution Process
Silica Gel Column Chromatography: Overview
Polar components tend to bind strongly to the silica gel, causing them to move slowly through the column. In contrast, nonpolar compounds...
Size-Exclusion Chromatography
Silica particles offer advantages such as rigidity,...
Ion Exchange
Gas Chromatography: Types of Columns and Stationary Phases