Degree of conversion of 3D printing resins used for splints and orthodontic appliances under different
Claire-Adeline Dantagnan1,2, Philippe François1,3, Stéphane Le Goff1
1Innovative Dental Materials and Interfaces Research Unit (URB2i), UR 4462, 1 Rue Maurice Arnoux, 92120, Montrouge, France.
Objectives:
To measure the degree of conversion (DC) of different 3D printing resins used for splints or orthodontic appliances under different postpolymerization conditions.
Materials And Methods:
Five 3D-printed photopolymer resins were studied. Each resin was analyzed in liquid form (n = 15), and then cylindrical specimens (n = 135) were additively manufactured and postcured with Form Cure (Formlabs) at different times (10, 60, and 90 min) and temperatures (20 °C, 60 °C, and 80 °C). The DC of each specimen was measured with Fourier transform infrared spectroscopy (FTIR). The data were statistically analyzed using a 3-way ANOVA followed by Tukey's post hoc test.
Results:
The time and temperature of postpolymerization significantly influenced the DC of each resin: when time and/or temperature increased, the DC increased. For all resins tested, the lowest DC was obtained with a postcuring protocol at 10 min and 20 °C, and the highest DC was obtained at 90 min and 80 °C. However, at 80 °C, the samples showed a yellowish color.
Conclusions:
With the Form Cure device, the time and temperature of postcuring could have an impact on the DC of the 3D printing resins studied. The DC of the 3D printing resins could be optimized by adjusting the postpolymerization protocol.
Clinical Relevance:
Regardless of the resin used, when using the Form Cure device, postcuring at 60 min and 60 °C would be the minimal time and temperature conditions for achieving proper polymerization. Beyond that, it would be preferable to increase the postcuring time to boost the DC.
More Related Videos
07:283D Printing and In Situ Surface Modification via Type I Photoinitiated Reversible Addition-Fragmentation Chain Transfer Polymerization
Published on: February 18, 2022
03:02Impact of Fabrication Techniques and Polishing Procedures on Surface Roughness of Denture Base Resins
Published on: January 17, 2025
Related Concept Videos
Polymer Classification: Stereospecificity
Polymer Classification: Architecture