Related Experiment Video
Updated: Aug 10, 2025

Setup of Consumer Wearable Devices for Exposure and Health Monitoring in Population Studies
Published on: February 3, 2023
Compliance Challenges in a Longitudinal COVID-19 Cohort Using Wearables for Continuous Monitoring: Observational
Mario Mekhael1, Chan Ho1, Charbel Noujaim1
1Tulane University School of Medicine, New Orleans, LA, United States.
Background:
The WEAICOR (Wearables to Investigate the Long Term Cardiovascular and Behavioral Impacts of COVID-19) study was a prospective observational study that used continuous monitoring to detect and analyze biometrics. Compliance to wearables was a major challenge when conducting the study and was crucial for the results.
Objective:
The aim of this study was to evaluate patients' compliance to wearable wristbands and determinants of compliance in a prospective COVID-19 cohort.
Methods:
The Biostrap (Biostrap USA LLC) wearable device was used to monitor participants' biometric data. Compliance was calculated by dividing the total number of days in which transmissions were sent by the total number of days spent in the WEAICOR study. Univariate correlation analyses were performed, with compliance and days spent in the study as dependent variables and age, BMI, sex, symptom severity, and the number of complications or comorbidities as independent variables. Multivariate linear regression was then performed, with days spent in the study as a dependent variable, to assess the power of different parameters in determining the number of days patients spent in the study.
Results:
A total of 122 patients were included in this study. Patients were on average aged 41.32 years, and 46 (38%) were female. Age was found to correlate with compliance (r=0.23; P=.01). In addition, age (r=0.30; P=.001), BMI (r=0.19; P=.03), and the severity of symptoms (r=0.19; P=.03) were found to correlate with days spent in the WEAICOR study. Per our multivariate analysis, in which days spent in the study was a dependent variable, only increased age was a significant determinant of compliance with wearables (adjusted R2=0.1; β=1.6; P=.01).
Conclusions:
Compliance is a major obstacle in remote monitoring studies, and the reasons for a lack of compliance are multifactorial. Patient factors such as age, in addition to environmental factors, can affect compliance to wearables.
Related Concept Videos
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac...
Holter Monitor: 24-Hour Monitoring
Longitudinal Studies
Longitudinal Research
Guidelines For Measuring Vital Signs
Before taking a patient's vital signs, a nurse would consider and assess the patient's comfort level and ensure appropriate equipment is available.
Special considerations while measuring oxygen saturation
Ensuring accuracy in vital sign recordings while prioritizing patient comfort and minimizing anxiety is...