Related Experiment Video
Updated: Aug 10, 2025

Author Spotlight: Advancing the Study of Brain-Heart Interplay with a Comprehensive EEGLAB Plugin for Multimodal Signal Analysis
Published on: April 26, 2024
Hybrid CNN-SVR Blood Pressure Estimation Model Using ECG and PPG Signals
Solmaz Rastegar1, Hamid Gholam Hosseini2, Andrew Lowe2
1PHD Media, Auckland 1024, New Zealand.
Abstract:
Continuous blood pressure (BP) measurement is vital in monitoring patients' health with a high risk of cardiovascular disease. The complex and dynamic nature of the cardiovascular system can influence BP through many factors, such as cardiac output, blood vessel wall elasticity, circulated blood volume, peripheral resistance, respiration, and emotional behavior. Yet, traditional BP measurement methods in continuously estimating the BP are cumbersome and inefficient. This paper presents a novel hybrid model by integrating a convolutional neural network (CNN) as a trainable feature extractor and support vector regression (SVR) as a regression model. This model can automatically extract features from the electrocardiogram (ECG) and photoplethysmography (PPG) signals and continuously estimates the systolic blood pressure (SBP) and diastolic blood pressure (DBP). The CNN takes the correct topology of input data and establishes the relationship between ECG and PPG features and BP. A total of 120 patients with available ECG, PPG, SBP, and DBP data are selected from the MIMIC III database to evaluate the performance of the proposed model. This novel model achieves an overall Mean Absolute Error (MAE) of 1.23 ± 2.45 mmHg (MAE ± STD) for SBP and 3.08 ± 5.67 for DBP, all of which comply with the accuracy requirements of the AAMI SP10 standard.
Related Concept Videos
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Neural Regulation of Blood Pressure
Baroreceptor Reflex
Baroreceptors, located in the carotid sinuses and aortic arch, detect changes in blood pressure. When blood pressure rises, these stretch-sensitive receptors...
Measurement of Blood Pressure
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac...
Pre-Procedural Guidelines for Assessing Blood Pressure

