Suture-based vs. pure plug-based vascular closure devices for VA-ECMO decannulation-A retrospective observational
Clemens Scherer1,2, Hans Theiss1,2, Mario Istrefi1
1Department of Medicine I, University Hospital, LMU Munich, Munich, Germany.
Frontiers in Cardiovascular Medicine
|February 13, 2023
Summary
Plug-based closure devices significantly reduce severe bleeding during veno-arterial extracorporeal membrane oxygenation (VA-ECMO) decannulation compared to suture-based devices. This suggests plug-based closure is a safer option for VA-ECMO removal.
Area of Science:
- Cardiovascular Medicine
- Interventional Cardiology
- Critical Care Medicine
Background:
- Veno-arterial extracorporeal membrane oxygenation (VA-ECMO) is crucial for cardiogenic shock.
- Complications during VA-ECMO decannulation can negatively impact patient outcomes.
- Effective vascular closure is essential for safe VA-ECMO removal.
Purpose of the Study:
- To compare the efficacy and safety of suture-based versus plug-based vascular closure devices for VA-ECMO decannulation.
- To evaluate bleeding events, ischemic complications, and pseudoaneurysm formation.
- To determine the preferred method for vascular closure post-VA-ECMO.
Main Methods:
- Retrospective study comparing 33 patients with suture-based closure devices (Perclose ProGlide) and 38 patients with plug-based closure devices (MANTA).
- Analysis of procedural outcomes, including device placement success, bleeding, ischemia, and pseudoaneurysm.
- Statistical comparison of complication rates between the two closure device groups.
Main Results:
- Technically correct device placement rates were 88% for suture-based and 97% for plug-based (p=0.27).
- Severe bleeding events were significantly reduced with plug-based devices (3%) compared to suture-based devices (21%) (p=0.04).
- Ischemic complications (6% vs. 5%) and pseudoaneurysm formation (3% vs. 3%) were similar between groups (p=1.00).
Conclusions:
- Plug-based vascular closure devices are associated with a significant reduction in severe bleeding during VA-ECMO decannulation.
- Plug-based closure should be considered the preferred option for VA-ECMO decannulation.
- Further validation through a randomized controlled trial is recommended.