Effect of void-carbon on blue-shifted luminescence in TADF molecules by theoretical simulations

Boyuan Zhang1, Haoyang Xu1, Yumin Xia1

  • 1State Key Laboratory for Modification of Chemical Fibers and Polymer Materials, College of Materials Science and Engineering, Donghua University, Shanghai, China.

Frontiers in Chemistry
|February 13, 2023
PubMed

Related Concept Videos

Variables Affecting Phosphorescence and Fluorescence01:26

Variables Affecting Phosphorescence and Fluorescence

Fluorescence and phosphorescence are essential phenomena in fields like analytical chemistry, biological imaging, and materials science, where they detect molecular properties and visualize cellular structures. Understanding the variables that influence these luminescent behaviors is crucial for maximizing accuracy and efficiency in their applications. These variables can broadly be grouped into chemical structure, solvent properties, and external conditions, each playing a distinct role in...
567
UV–Vis Spectroscopy: Molecular Electronic Transitions01:16

UV–Vis Spectroscopy: Molecular Electronic Transitions

In Ultraviolet–Visible (UV–Vis) spectroscopy, the absorption of electromagnetic radiation is used to probe the electronic structure of molecules. This technique provides insights into molecular electronic transitions, particularly the movement of electrons between different molecular orbitals. Radiation is absorbed if the energy of the electromagnetic radiation passing through the molecule is precisely equal to the energy difference between the excited and ground states. During this...
1.7K
π Electron Effects on Chemical Shift: Aromatic and Antiaromatic Compounds01:14

π Electron Effects on Chemical Shift: Aromatic and Antiaromatic Compounds

In aromatic compounds, such as benzene, the circulation of (4n + 2) π-electrons sets up a diamagnetic or diatropic ring current around the perimeter of the molecule. This current induces a magnetic field that opposes the external field inside the ring and reinforces it on the outside. The protons in benzene are deshielded and exhibit high chemical shifts in the range 6.5–8.5 ppm. The shielding effect at the center of the ring is evident in complex aromatic molecules, such as...
1.2K
Chemical Shift: Internal References and Solvent Effects01:17

Chemical Shift: Internal References and Solvent Effects

In an NMR sample, precise measurement of the absolute absorption frequencies of nuclei is difficult. A standard internal reference compound is added, and the frequency difference between the reference signal and sample signals is measured.
The internal reference compound generally used in NMR spectroscopy is tetramethylsilane (TMS). TMS is preferred because it is chemically inert, soluble in NMR solvents, and easily removable. Also, the highly shielded methyl protons in TMS yield an intense...
706
π Electron Effects on Chemical Shift: Overview01:27

π Electron Effects on Chemical Shift: Overview

An applied magnetic field causes loosely bound π-electrons in organic molecules to circulate, producing a local or induced diamagnetic field over a large spatial volume. As the molecules tumble in solution, the field generated by π-electrons in spherical substituents results in a zero net field. However, the net field generated by π-electrons in non-spherical substituents is not zero. The effect of this induced field depends on the orientation of the molecule with respect to B0,...
1.1K
Photoluminescence: Applications01:14

Photoluminescence: Applications

Photoluminescence offers a wide range of applications due to its inherent sensitivity and selectivity. This technique allows for both direct and indirect analyses of the analyte. Direct quantitative analysis is possible when the analyte exhibits a favorable quantum yield for fluorescence or phosphorescence. However, an indirect analysis may be feasible if the analyte is not fluorescent or phosphorescent, or if the quantum yield is unfavorable. Indirect methods include reacting the analyte with...
463