Related Experiment Video
Updated: Aug 10, 2025

Veno-Venous Extracorporeal Membrane Oxygenation in a Mouse
Published on: October 24, 2018
Association Between Mortality and Ventilator Parameters in Children With Respiratory Failure on ECMO
Tadashi R Miya1, Jamie M Furlong-Dillard2, Johnna M Sizemore2
1Division of Pediatric Critical Care Medicine, Department of Pediatrics, University of Utah, Salt Lake City, Utah. tadashi.miya@hsc.utah.edu.
Background:
In refractory respiratory failure, extracorporeal membrane oxygenation (ECMO) is a rescue therapy to prevent ventilator-induced lung injury. Optimal ventilator parameters during ECMO remain unknown. Our objective was to describe the association between mortality and ventilator parameters during ECMO for neonatal and pediatric respiratory failure.
Methods:
We performed a secondary analysis of the Bleeding and Thrombosis on ECMO dataset. Ventilator parameters included breathing frequency, tidal volume, peak inspiratory pressure, PEEP, dynamic driving pressure, pressure support, mean airway pressure, and FIO2 . Parameters were evaluated before cannulation, on the calendar day of ECMO initiation (ECMO day 1), and the day before ECMO separation.
Results:
Of 237 included subjects analyzed, 64% were neonates, of whom 36% had a congenital diaphragmatic hernia. Of all the subjects, 67% were supported on venoarterial ECMO. Overall in-hospital mortality was 35% (n = 83). The median (interquartile range) PEEP on ECMO day 1 was 8 (5.0-10.0) cm H2O for neonates and 10 (8.0-10.0) cm H2O for pediatric subjects. By multivariable analysis, higher PEEP on ECMO day 1 in neonates was associated with lower odds of in-hospital mortality (odds ratio 0.77, 95% CI 0.62-0.92; P = .01), with a further amplified effect in neonates with congenital diaphragmatic hernia (odds ratio 0.59, 95% CI 0.41-0.86; P = .005). No ventilator type or parameter was associated with mortality in pediatric subjects.
Conclusions:
Avoiding low PEEP on ECMO day 1 for neonates on ECMO may be beneficial, particularly those with a congenital diaphragmatic hernia. No additional ventilator parameters were associated with mortality in either neonatal or pediatric subjects. PEEP is a modifiable parameter that may improve neonatal survival during ECMO and requires further investigation.
More Related Videos
03:40Point-of-Care Ultrasound for Peripheral Veno-Arterial Extracorporeal Membrane Oxygenation Without Left Ventricular Venting
Published on: January 17, 2025
06:22Surfactant Depletion Combined with Injurious Ventilation Results in a Reproducible Model of the Acute Respiratory Distress Syndrome ARDS
Published on: April 7, 2021
Related Concept Videos
Mechanical Ventilation I: Indication and Settings
Factors Affecting Pulmonary Ventilation
Alveolar Surface Tension
The alveolar fluid lines the luminal surface of the alveoli and exerts a force called surface tension. This force is caused by the polar water molecules in the liquid being more strongly attracted to each...
Mechanical Ventilation III: Noninvasive Ventilation
Noninvasive Positive-Pressure Ventilation...
Acute Respiratory Failure-V
Ensure that patients are monitored continuously for their response to therapy, including changes in...
Mechanical Ventilation II: Invasive Ventilation
Negative-Pressure Ventilators
Negative-pressure ventilators create a vacuum around the chest or body to draw air into the lungs, simulating breathing. This method does not require an...
Acute Respiratory Failure-II
The underlying physiological abnormalities that contribute to hypoxemic respiratory failure include: