Related Experiment Video
Updated: Aug 9, 2025

High-frequency Ultrasound Imaging of Mouse Cervical Lymph Nodes
Published on: July 25, 2015
Nodules Identified on Surveillance Ultrasound for HCC: CEUS or MRI as the Initial Test?
Jinghui Hu1, David P Burrowes1, Benjamin A Caine1
1Department of Radiology, University of Calgary, Calgary, Alberta, Canada.
Objectives:
Following positive surveillance ultrasound (US), magnetic resonance imaging (MRI) is recommended for further characterization. We propose contrast-enhanced ultrasound (CEUS) shows equivalent efficacy.
Methods:
This prospective institutional review board approved study recruited 195 consecutive at-risk patients with a positive surveillance US. All had CEUS and MRI. Biopsy (n = 44) and follow-up are gold standard. MRI and CEUS results are classified according to liver imaging reporting and data system (LI-RADS) and patient outcome.
Results:
As an US-based modality, CEUS is superior in confirming findings from surveillance US, correlation in 189/195 (97%) on CEUS compared to 153/195 (79%) on MRI. Within these negative MRI examinations, there are 2 hepatocellular carcinoma (HCC) and 1 cholangiocarcinoma (iCCA) diagnosed on CEUS and proven by biopsy. From 195 patients, there are 71 malignant diagnoses from all sources, including 58 LR-5 (45 on MRI and 54 on CEUS) and 13 others, including HCC outside of LR-5 category, and LR-M with biopsy proven iCCA (3 on MRI and 6 on CEUS). CEUS and MRI show concordant results in the majority of patients (146/195, 75%), including 57/146 malignant and 89/146 benign diagnoses. There are 41/57 concordant LR-5 and 6/57 concordant LR-M. When CEUS and MRI are discordant, CEUS upgraded 20 (10 biopsy-proven) from MRI LR-3/4 to CEUS LR-5 or LR-M by showing washout (WO) that MRI failed to show. Additionally, CEUS characterized time and intensity of WO and diagnosed 13/20 LR-5 by showing late and weak WO and 7 LR-M by showing fast and marked WO. CEUS is 81% sensitive and 92% specific in diagnosing malignancy. MRI is 64% sensitive and 93% specific.
Conclusions:
CEUS performance is at least equivalent if not superior to MRI for initial evaluation of lesions from surveillance US.
More Related Videos
05:56Evaluation of the Feasibility, Safety, and Accuracy of an Intraoperative High-intensity Focused Ultrasound Device for Treating Liver Metastases
Published on: January 9, 2019
05:19Magnetic Resonance Imaging Assessment of Carcinogen-induced Murine Bladder Tumors
Published on: March 29, 2019
Related Concept Videos
Ultrasound II: Endoscopic Ultrasound and FibroScan
Endoscopic Ultrasound (EUS):
Ultrasonography
During an ultrasonography procedure, a handheld device called...
Imaging Studies II: Ultrasonography
Imaging Studies III: Computed Tomography
Imaging Studies VI: Voiding Cystourethrography and Cystography