Device-evaluated autonomic nervous function for predicting ventricular arrhythmias and all-cause mortality in
Chendi Cheng1, Jiang Jiang1, Keping Chen1
1State Key Laboratory of Cardiovascular Disease, Arrhythmia Center, National Center for Cardiovascular Diseases, Fuwai Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, China.
Abstract:
Introduction: Autonomic nervous system (ANS) function quantified by heart rate variability (HRV) was associated with long-term prognosis, but it was rarely used in the evaluation of patients with heart failure, especially those with cardiac resynchronization therapy-defibrillator (CRT-D) implantation. This study aimed to describe the changes in ANS function among patients who underwent CRT-D with remote home monitoring function, and explore predictive value of HRV for ventricular tachyarrhythmias (VTAs) and all-cause mortality. Method: Patients who underwent CRT-D implantation were included. Device-measured all-day HR, night-time HR, and HRV (measured by the standard deviation of the atrial-atrial sensed intervals) were used to quantify ANS function. Multivariate Cox proportional hazards models were fitted to calculate hazard ratios (HRs) and 95% confidence intervals (CIs) of VTAs or all-cause mortality in relation to ANS function at baseline and 6 months post-implantation. The cutoff value was determined using restrictive cubic splines. Multivariable logistic regression was further established to determine factors influencing postoperative HRV. Results: A total of 170 patients treated with CRT-D were eligible for analysis. During a median follow-up period of 50.8 months, 61 patients died and 69 patients experienced at least one spontaneous episode of VTAs. At 6 months after CRT implantation, 114 patients showed improvement in HRV, increasing from 66.4 ± 19.4 ms to 76.7 ± 21.2 ms. The postoperative HRV was associated with both all-cause mortality (HRs: 0.983; 95% CI: 0.968 to 0.998, p = 0.012) and VTAs (HRs: 0.973; 95% CI: 0.954 to 0.993, p = 0.008), and the relative risk would significantly increase when the postoperative HRV lower than 75 ms. After adjusting for basic ANS function and possible influencing factors, patients without diabetes (p = 0.018) and with higher daily physical activity (p = 0.041) could maintain higher postoperative HRV after CRT implantation. Conclusion: More than two-thirds of heart failure patients showed improvement in ANS function following CRT treatment. However, patients with diabetes and low daily physical activity levels have difficulty maintaining a higher postoperative HRV, which is associated with a worse clinical outcome.
More Related Videos
12:45Benefits of Cardiac Resynchronization Therapy in an Asynchronous Heart Failure Model Induced by Left Bundle Branch Ablation and Rapid Pacing
Published on: December 11, 2017
08:28Methods for ECG Evaluation of Indicators of Cardiac Risk, and Susceptibility to Aconitine-induced Arrhythmias in Rats Following Status Epilepticus
Published on: April 5, 2011
Related Concept Videos
Dysrhythmias V: Evaluating Dysrhythmias
Cardiomyopathy II: Dilated Cardiomyopathy
ECG Interpretation of Arrhythmias II: Atrial, Junctional and Ventricular Arrhythmias
Cardiopulmonary Resuscitation III: AED Use