Related Experiment Video
Updated: Aug 9, 2025

Author Spotlight: Advancing Awake Nasotracheal Intubation with Flexible Video Rhino-Laryngoscopes
Published on: August 2, 2024
Factors Influencing the Time of Intubation Using C-MAC D-Blade® Video Laryngoscope: An Observational Cross-Sectional
Balasubramaniam Gayathri1, Karthik Mani1, Manoj Vishak1
1Anaesthesiology, SRM Medical College Hospital and Research Centre, Chennai, IND.
Abstract:
Purpose C-MAC D-Blade® (Karl Storz, Tuttlingen, Germany) video laryngoscope (VL) has proved to be of immense utility in difficult intubation. But unfortunately, in an urgent situation, the predictable correct curvature of the endotracheal tube for effortless intubation is not met. We hypothesized that expertise is the most important variable in intubation and that novice students will be unable to intubate if the angle of curvature is incorrect. Methods An observational cross-sectional study was planned with 30 anesthesia residents, categorized into three groups based on their expertise in laryngoscopy. Students had to intubate an airway mannequin using the C-MAC D-Blade® VL with three different stylet angulations. The curvatures were 80, 100, and 120 degrees, which are commonly encountered in routine day-to-day practice. The time to get a stable glottic view, time to intubate, and ease of intubation were measured. Results The mean time to intubate was the least with 100-degree angulation in group C (19.60 ± 0.97) while the maximum time was in group A with 80-degree angulation (61.49 ± 3.69). A significant difference was noted in time to get a stable glottic view when compared between the groups. There was no difference in time to intubate with different stylet angulations when compared between groups. Conclusions Novices and experts could intubate even if the angle of curvature was incorrect taking more time. The time to laryngoscopy is significantly dependent on experience, but the time to intubate is influenced by the angle of curvature of the stylet.
Related Concept Videos
Cardiopulmonary Resuscitation V: Advanced Airway Management Techniques
Endotracheal Intubation I: Procedure
The ET tube comprises various components, including a standard adaptor to attach a bag-valve-mask (BVM) or ventilator, a cuff, a pilot balloon, and radiopaque markings along its length to measure the insertion distance. The tube sizes...
Endotracheal Intubation II: Nursing Management
1. Nursing Care of Patients Before Intubation
Before the endotracheal intubation procedure, nurses play an essential role in ensuring the process goes smoothly. The nurses must be familiar with intubation...
Endotracheal Tube Extubation
Procedure
Extubation removes the endotracheal tube (ETT) from the patient on mechanical ventilation. It requires a well-coordinated, multidisciplinary approach involving physicians, nurses, respiratory therapists, and other healthcare professionals....
Cardiopulmonary Resuscitation II: ACLS Airway Management
Tracheostomy Care I: Pre-procedural Steps
Required Equipment
The equipment necessary for tracheostomy care includes: