Related Experiment Video
Updated: Oct 4, 2026

Assessment of Ex Vivo Murine Biventricular Function in a Langendorff Model
Published on: December 23, 2022
A beat-to-beat calculator for the diastolic pressure time index and the tension time index
1Information Science Laboratory for Biomedicine, Kyushu University Hospital, Fukuoka, Japan.
Abstract:
We have developed a beat-to-beat calculator which can calculate in real-time the ratio of the diastolic pressure time index (DPTI), and the tension time index (TTI) as an index of the myocardial oxygen supply/demand balance. Physicians set up presumed value for the left ventricular endodiastolic pressure, a search area for the dicrotic notch, a threshold for the onset of the up-slope and the corresponding value of the calibration signal on the digital switches of the calculator. Next, the arterial pressure analog signal is input into the calculator. The calculator searches automatically for both the onset of the up-slope and the dicrotic notch. The arterial pressure curve is displayed beat-to-beat with the recognized onset and the dicrotic notch on the CRT to be confirmed by physicians. When physicians do not agree with the automatic recognition they can fit the automatic recognition to the observation. If the recognition of the onset is inadequate, the threshold can be re-adjusted to trigger the onset. If recognition of the dicrotic notch is inadequate, the physician can adjust the search-area. Therefore, physicians who operate the calculator can rely on the calculated DPTI/TTI. This calculator can continuously monitor the myocardial oxygen supply/demand balance in patients with acute myocardial infarction or just after open-heart surgery.
More Related Videos
Related Concept Videos
Pulse
Pulse Rate and its Significance
Pulse rate, often measured in beats per minute (bpm), reflects the heart rate (HR), which is influenced by numerous factors such as stress, physical activity, and hormonal changes. A normal resting adult pulse rate falls between...
Sites for measuring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Assessment of blood pressure in brachial artery(two-step method)
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Pulse
The pulse serves as a clinical indicator...