Related Experiment Video
Updated: Aug 8, 2025

AC Electrokinetic Phenomena Generated by Microelectrode Structures
Published on: July 28, 2008
Influence of the Ground Electrode on the Dynamics of Electrowetting
Iftekhar Khan1, Stefania Castelletto2, Gary Rosengarten2
1Future Technologies, College of VE, RMIT University, Melbourne, VIC 3000, Australia.
Abstract:
The ability to manipulate a liquid meniscus using electrowetting has many applications. In any electrowetting design, at least two electrodes are required: one forms the field to change the contact angle and the other functions as a ground electrode. The contribution of the ground electrode (GE) to the dynamics of electrowetting has not yet been thoroughly investigated. In this paper, we discovered that with a bare ground electrode, the contact angle of a sessile drop increases instead of decreases when a direct current (DC) voltage varying from zero to the threshold voltage is applied. This phenomenon is opposite to what occurs when the GE is coated with a dielectric, where the contact-angle change follows the Lippmann-Young equation above the threshold voltage of electrowetting. However, this behaviour is not observed with either a dielectric-coated electrode using direct current (DC) or a bare ground electrode using alternating current (AC) voltage electrowetting. This study explains this phenomenon with finite element simulation and theory. From previous research work, the ground electrode configuration is inconsistent. In some studies, the ground electrode is exposed to water; in other studies, the ground electrode is covered with dielectric. This study identified that an exposed ground electrode is not required in electrowetting. Moreover, this research work suggests that for applications where precise control of the contact angle is paramount, a dielectric-coated ground electrode should be used since it prevents the increase in the contact angle when increasing the applied potential from zero to the threshold voltage. This study also identified that contact angle hysteresis is lower with a Cytop-coated ground electrode and DC voltage than with a bare ground electrode using AC or DC voltages.
Related Concept Videos
Electrostatic Boundary Conditions in Dielectrics
Consider a case where both the mediums across a boundary are two different dielectric materials. Recall that the electric field and electric displacement are proportional and related through the material's...
Potentiometry: Types of Electrodes
The Standard Hydrogen Electrode (SHE) is a widely used reference electrode that maintains zero potential across all temperatures. However, its need for a continuous hydrogen gas supply renders it impractical for everyday use.
An alternative to SHE is the Saturated Calomel Electrode (SCE). This electrode features an...
Electrodeposition
Electrodeposition can...
Electrogravimetric Analysis: Overview
To test the completeness of the...
Interfacial Electrochemical Methods: Overview
Standard Electrode Potentials

