Related Experiment Video
Updated: Aug 8, 2025

Electroporation of Mycobacteria
Published on: May 23, 2008
Vancomycin-Resistant Enterococcus faecium Sterilization and Conductivity Change by Impulse Voltage
Takahisa Ueno1, Takashi Furukawa2, Takashi Sakugawa3
1Department of Electrical and Electronic Engineering, National Institute of Technology, Oita College, 1666 Maki, Oita-shi 870-0152, Oita, Japan.
Impulse voltage effectively inactivates drug-resistant bacteria in wastewater, offering a promising alternative to chlorine sterilization. Sterilization efficiency is enhanced by higher temperatures and electrical conductivity.
Area of Science:
- Environmental microbiology
- Water treatment technologies
- Antimicrobial resistance
Background:
- Antibiotic resistance, particularly vancomycin resistance, is a growing global health concern.
- Conventional chlorine-based sewage sterilization may be insufficient to eliminate resistant bacteria.
- There is a need for effective methods to inactivate drug-resistant bacteria in wastewater.
Purpose of the Study:
- To investigate the efficacy of impulse voltage as a sterilization method for drug-resistant bacteria.
- To determine the optimal conditions for impulse-voltage-mediated bacterial inactivation.
- To explore the correlation between sterilization rate and physical parameters like temperature and conductivity.
Main Methods:
- Application of impulse voltage to bacterial suspensions containing drug-resistant strains.
- Varying applied voltage (above 4.5 kV) and application times.
- Monitoring bacterial inactivation rates (CFU/mL).
- Measuring temperature and electrical conductivity of the bacterial suspension.
Main Results:
- Sterilization of bacteria at concentrations above 10^5 CFU/mL was achieved with impulse voltages above 4.5 kV and sufficient application time.
- Sterilization effectiveness increased with higher temperatures of the bacterial suspension.
- A correlation was observed between the number of sterilized bacteria and electrical conductivity when exceeding 10^5 CFU/mL.
Conclusions:
- Impulse voltage is a viable method for inactivating drug-resistant bacteria in wastewater.
- Sterilization efficiency is influenced by voltage, application time, temperature, and electrical conductivity.
- Electrical conductivity can serve as a rapid indicator for estimating sterilization rates, eliminating the need for traditional culture methods.
More Related Videos
10:34The Fabrication and Operation of a Continuous Flow, Micro-Electroporation System with Permeabilization Detection
Published on: January 7, 2022
10:12Monitoring Electroporation-Induced Changes in Action Potential Generation in Genetically Engineered Tet-On Spiking HEK cells
Published on: September 6, 2024
Related Concept Videos
Methods of Sterilization I: Physical Methods
Steam sterilization uses non-toxic, low-cost moist heat in the form of saturated steam under pressure, which is fast, microbicidal, and sporicidal, and quickly warms and penetrates fabrics. Autoclaves, or steam sterilizers, expose each item to direct steam contact for a predetermined time at the necessary...
Methods of Sterilization II: Chemical Methods
Using chemical sterilization rather than heat to clean out equipment is recommended. It eradicates and removes all bacteria,...
Antimicrobial Effectiveness
Physical Methods for Controlling Microbial Growth: Radiation and Filtration
Van de Graaff Generator
Van de Graaff uses both smooth and pointed surfaces, conductors, and insulators to generate large static charges and, hence, large voltages. A substantial excess charge can be deposited on the sphere because it moves...
Voltammetry: Factors Affecting Measurements