Chromium measurement in pharmaceutical samples: a comparative study of three new membrane electrodes with different
Parviz Ebadi Vazifekhoran1, Leila Hajiaghababaei1, Mohammad Reza Allahgholi Ghasri1
1Department of Chemistry, Yadegar-e-Imam Khomeini (RAH) Shahre Rey Branch, Islamic Azad University, Tehran, Iran. lhajiaghababaei@yahoo.com.
Abstract:
The present study deals with synthesis of N-(thiazol-2-ylcarbamothioyl) benzamide. It was utilized as a neutral ionophore for designing three types of chromium(III) sensors including coated wire ion selective electrodes (CW-ISEs), ion selective electrodes with liquid internal electrolyte (LIE-ISEs), and solid-state ion selective electrodes (SS-ISEs). UV-visible spectrophotometry was used to confirm the affinity of N-(thiazol-2-ylcarbamothioyl) benzamide to chromium(III). It was found that a membrane with a composition of 2% NaTPB, 8% ionophore, 60% DBP, and 30% PVC showed the best performance and a Nernstian slope of 21.6 mV per decade. Scanning electron microscopy was used to assess the PVC membrane morphology. The existence of chromium(III) in the liquid membrane matrix was proved by energy-dispersive X-ray spectroscopy. Detection limits for SS-ISE (1 × 10-6 M) and CW-ISE (1 × 10-6 M) were enhanced relative to LIE-ISE (1 × 10-5 M). All three electrodes showed a response time of about 5 s. The sensors' applicable pH range was 4.0-6.0. Fourier transform infrared spectra recorded through the electrode membrane showed that chromium(III) ion can interact with sulfur, nitrogen and oxygen atoms of N-(thiazol-2-ylcarbamothioyl) benzamide. The sensors were utilized as indicator electrodes in chromium(III) potentiometric titration with ethylenediaminetetraacetic acid and for directly measuring chromium(III) in some pharmaceutical samples.
Related Concept Videos
Ion-Exchange Chromatography
Potentiometry: Membrane Electrodes
Capillary Electrophoresis: Applications
Capillary zone electrophoresis (CZE) separates ionic components based on their electrophoretic mobility. It has been used to separate proteins, amino acids,...
Potentiometry: Types of Electrodes
The Standard Hydrogen Electrode (SHE) is a widely used reference electrode that maintains zero potential across all temperatures. However, its need for a continuous hydrogen gas supply renders it impractical for everyday use.
An alternative to SHE is the Saturated Calomel Electrode (SCE). This electrode features an...
High-Performance Liquid Chromatography: Types of Detectors
Ion Exchange