Partitioning-Induced Isolation of Analyte and Analysis via Multiscaled Aqueous Two-Phase System
Yang Cao1, Jingxuan Tian2, Haisong Lin1,2
1Department of Mechanical Engineering, The University of Hong Kong, Pokfulam Road, Hong Kong SAR 999077, China.
Abstract:
Most fluorescence-based bioanalytical applications need labeling of analytes. Conventional labeling requires washing to remove the excess fluorescent labels and reduce the noise signals. These pretreatments are labor intensive and need specialized equipment, hindering portable applications in resource-limited areas. Herein, we use the aqueous two-phase system (ATPS) to realize the partitioning-induced isolation of labeled analytes from background signals without extra processing steps. ATPS is formed by mixing two polymers at sufficiently high concentrations. ATPS-based isolation is driven by intrinsic affinity differences between analytes and excess labels. To demonstrate the partitioning-induced isolation and analysis, fluorescein isothiocyanate (FITC) is selected as the interfering fluorophore, and a monoclonal antibody (IgG) is used as the analyte. To optimize ATPS compositions, different molecular weights and mass fractions of polyethylene glycol (PEG) and dextran and different phosphate-buffered saline (PBS) concentrations are investigated. Various operational scales of our approach are demonstrated, suggesting its compatibility with various bioanalytical applications. In centimeter-scale ATPS, the optimized distribution ratios of IgG and FITC are 91.682 and 0.998 using PEG 6000 Da and dextran 10,000 Da in 10 mM PBS. In millimeter-scale ATPS, the analyte is enriched to 6.067 fold using 15 wt % PEG 35,000 Da and 5 wt % dextran 500,000 Da in 10 mM PBS. In microscale ATPS, analyte dilutions are isolated into picoliter droplets, and the measured fluorescence intensities linearly correlated with the analyte concentrations (R2 = 0.982).
Related Concept Videos
Analyte Adsorption and Distribution
Size-Exclusion Chromatography
Silica particles offer advantages such as rigidity,...
Capillary Electrophoresis: Applications
Capillary zone electrophoresis (CZE) separates ionic components based on their electrophoretic mobility. It has been used to separate proteins, amino acids,...
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...
High-Performance Liquid Chromatography: Introduction
In HPLC, two phases play a critical role in the separation process:
Ion-Exchange Chromatography