Agreement of Oscillometric and Auscultatory blood pressure measurement methods: An ambulance noise simulation study
Ali Cankut Tatliparmak1, Sarper Yilmaz2
1Dept. of Emergency Medicine, Kolan International Hospital, Istanbul, Turkey.
Objective:
Although noise is known to negatively affect blood pressure (BP) measurements, its impact on different BP measurement methods remains unclear. The aim of this study is to compare the agreement of oscillometric and auscultatory BP measurement methods under in-ambulance noise levels.
Methods:
This method-comparison study was conducted on 50 healthy volunteers in a tertiary emergency department (ED). Participants were divided into two groups of 25, and BP was measured using auscultatory and oscillometric methods in noisy and ambient environments by 2 emergency medicine technicians (EMT). The primary object of the study was to compare the agreement of auscultatory mercury sphygmomanometers and automated auscillometric BP measurements in ambient and noisy environments.
Results:
We examined the agreement between auscultative and oscillometric measurements of BP conducted in an ambient environment (46.75 [IQR (41.2--55.18)] dB) and found that both systolic and diastolic BP were within the level of agreement (LoA) established before the study (systolic BP [-13.96 to 8.48 mmHG], diastolic BP [-7.44 to 8.08 mmHg]); whereas, in noisy environment (92.35 [IQR 88-96.55] dB) both systolic and diastolic BP were outside the range of LoA (systolic BP [-37.77 to 9.94 mmHg], diastolic BP [-21.73 to 16.37 mmHg]). Additionally, we found that in ambient environments, concordance correlation coefficients were higher than in noisy environments (0.943 [0.906-0.966], 0.957 [0.93-0.974]; 0.574 [0.419-0.697], 0.544 [0.326-0.707]; systolic and diastolic BP, respectively).
Conclusion:
The results of this study demonstrate that noise significantly affects the agreement between oscillometric and auscultatory blood pressure measurement methods.
More Related Videos
11:26Assessing Cerebral Autoregulation via Oscillatory Lower Body Negative Pressure and Projection Pursuit Regression
Published on: December 10, 2014
14:09Tilt Testing with Combined Lower Body Negative Pressure: a "Gold Standard" for Measuring Orthostatic Tolerance
Published on: March 21, 2013
Related Concept Videos
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Sites for measruring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement
Measurement of Blood Pressure
Assessment of blood pressure in brachial artery(two-step method)