Related Experiment Video
Updated: Aug 7, 2025

Evaluation of Capnography Sampling Line Compatibility and Accuracy when Used with a Portable Capnography Monitor
Published on: September 29, 2020
Changes in Oxygen Saturation During Fiberoptic Bronchoscopy: High-Flow Nasal Cannula versus Standard Oxygen Therapy
Pedro Pablo Arias-Sanchez1, Gabriela Ledesma2, Johana Cobos1,3
1Intermediate Care Unit, Hospital Vicente Corral Moscoso, Cuenca, Ecuador.
Background:
Hypoxemia is a relatively common complication in stable patients during fiberoptic bronchoscopy (FOB). To prevent this complication, high-flow nasal cannula (HFNC) has been described as an alternative to standard oxygen therapy. However, the advantages of HFNC over standard oxygen therapy in acute care patients receiving supplemental oxygen before FOB performed with an oral approach are unknown.
Methods:
We conducted an observational study that involved subjects with a presumptive diagnosis of pneumonia and a clinical indication for a bronchial aspirate sample. The type of oxygen support (standard oxygen therapy vs HFNC) was selected according to availability. The oxygen flow in the HFNC group was 60 L/min. In both groups, the FIO was set at 0.40. Hemodynamic, respiratory dynamics, and gas exchange data were collected at baseline, before, during, and 24 h after FOB.
Results:
Forty subjects were included, 20 in each group (HFNC and standard oxygen therapy). The study was performed on day 5 of hospitalization in the HFNC group and on day 4 in the standard oxygen therapy group (P = .10). No significant between-group differences in baseline characteristics were observed. HFNC vs standard oxygen therapy was associated with a smaller decrease in SpO levels during the procedure (94% vs 90%; P = .040, respectively) and with less variation between the last SpO measured before FOB and the lowest SpO during FOB (Δ SpO ): 2% versus 4.5% (P = .01, respectively).
Conclusions:
In acute subjects who required oxygen support before FOB, the use of HFNC during FOB with an oral approach was associated with a smaller decrease in SpO and lower Δ SpO compared with standard oxygen therapy.
More Related Videos
14:28Non-Invasive Monitoring of Microvascular Oxygenation and Reactive Hyperemia using Hybrid, Near-Infrared Diffuse Optical Spectroscopy for Critical Care
Published on: May 10, 2024
07:52Expired CO2 Measurement in Intubated or Spontaneously Breathing Patients from the Emergency Department
Published on: January 29, 2011
Related Concept Videos
Oxygen Delivering System I: Nasal Cannula and Face Mask
Nasal Cannula
A nasal cannula is a lightweight tube split at one end into two prongs and placed in the nostrils. It is typically used to deliver low to medium levels of oxygen.
Suggested flow rate: The suggested flow rate for a nasal cannula typically ranges between 1 and 6 L/min.
Oxygen percentage setting:...
Administering Oxygen by Nasal Cannula
Nasal Cannulas
A nasal cannula is a lightweight tube split into two prongs placed in the nostrils,...
Assessment of Diffusion and Perfusion
The Role of Diffusion in Respiration
Diffusion is the process by which molecules move from an area of higher concentration to an area of lower concentration. In the respiratory system, this...
Special considerations while measuring oxygen saturation
Ensuring accuracy in vital sign recordings while prioritizing patient comfort and minimizing anxiety is...
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...
Pulse Oximetry
Purpose
Average SpO2 values are greater than 95%. If the readings fall below 90%, it indicates that...