Related Experiment Video
Updated: Aug 7, 2025

Machine Learning Algorithms for Early Detection of Bone Metastases in an Experimental Rat Model
Published on: August 16, 2020
Development and validation of a CT-based radiomics signature for identifying high-risk neuroblastomas under the
Haoru Wang1, Mingye Xie1, Xin Chen1
1Department of Radiology, Children's Hospital of Chongqing Medical University, National Clinical Research Center for Child Health and Disorders, Ministry of Education Key Laboratory of Child Development and Disorders, Chongqing Key Laboratory of Pediatrics, Chongqing, China.
Background:
To develop and validate a radiomics signature based on computed tomography (CT) for identifying high-risk neuroblastomas.
Procedure:
This retrospective study included 339 patients with neuroblastomas, who were classified into high-risk and non-high-risk groups according to the revised Children's Oncology Group classification system. These patients were then randomly divided into a training set (n = 237) and a testing set (n = 102). Pretherapy CT images of the arterial phase were segmented by two radiologists. Pyradiomics package and FeAture Explorer software were used to extract and process radiomics features. Radiomics models based on linear discriminant analysis (LDA), logistic regression (LR), and support vector machine (SVM) were constructed, and the area under the curve (AUC), 95% confidence interval (CI), and accuracy were calculated.
Results:
The optimal LDA, LR, and SVM models had 11, 12, and 14 radiomics features, respectively. The AUC of the LDA model in the training and testing sets were 0.877 (95% CI: 0.833-0.921) and 0.867 (95% CI: 0.797-0.937), with an accuracy of 0.823 and 0.804, respectively. The AUC of the LR model in the training and testing sets were 0.881 (95% CI: 0.839-0.924) and 0.855 (95% CI: 0.781-0.930), with an accuracy of 0.823 and 0.804, respectively. The AUC of the SVM model in the training and testing sets were 0.879 (95% CI: 0.836-0.923) and 0.862 (95% CI: 0.791-0.934), with an accuracy of 0.827 and 0.804, respectively.
Conclusions:
CT-based radiomics is able to identify high-risk neuroblastomas and may provide additional image biomarkers for the identification of high-risk neuroblastomas.