Related Experiment Video
Updated: Aug 7, 2025

Retinal Pigment Epithelium Transplantation in a Non-human Primate Model for Degenerative Retinal Diseases
Published on: June 14, 2021
Amniotic Membrane Patching to Assist Closure of Recalcitrant Macular Holes
Background And Objective:
This study reports a case series of patients with persistent macular holes (MHs) who underwent human amniotic membrane subretinal placement to achieve successful anatomic MH closure.
Patients And Methods:
This was a retrospective case series of patients with persistently open full-thickness MHs who underwent human amniotic membrane placement. Patients were observed up to 6 months postoperatively.
Results:
Ten patients were included. The mean preoperative best-corrected visual acuity was 1.6 logMAR (20/800). Postoperatively, mean best-corrected visual acuity improved to 1.3 logMAR (20/400) at 1 month and 1.1 logMAR (20/250) by the 3- and 6-month visits. In all cases, the MH appeared closed at the 1-week visit and remained closed at their last follow-up. Optical coherence tomography showed closure in all cases. No adverse events were reported.
Conclusions:
Human amniotic membrane sub-retinal placement may serve as a useful surgical technique to assist in the closure of recalcitrant macular holes. [.