Related Experiment Video
Updated: Aug 7, 2025

Using Synchrotron Radiation Microtomography to Investigate Multi-scale Three-dimensional Microelectronic Packages
Published on: April 13, 2016
In situ wet pharmaceutical granulation captured using synchrotron radiation based dynamic micro-CT
Xiao Fan Ding1, Sima Zeinali Danalou2, Lifeng Zhang2
1Division of Biomedical Engineering, University of Saskatchewan, 57 Campus Drive, Saskatoon, SK, S7N 5A9, Canada.
Dynamic micro-computed tomography (micro-CT) using synchrotron radiation captures the rapid internal structural changes during pharmaceutical wet granulation. This non-destructive technique reveals granule consolidation, porosity evolution, and aggregate effects in real-time.
Area of Science:
- Pharmaceutical Sciences
- Materials Science
- Imaging Techniques
Background:
- Wet granulation is a key pharmaceutical process for producing tablets and capsules.
- Granule microstructure significantly impacts final product performance.
- Traditional imaging methods are too slow to capture dynamic granulation events.
Purpose of the Study:
- To demonstrate the capability of synchrotron radiation-based dynamic micro-computed tomography (micro-CT) for studying wet granulation.
- To investigate the evolving internal microstructure of pharmaceutical granules during the granulation process.
- To provide quantitative insights into early-stage wet granulation dynamics.
Main Methods:
- Utilized synchrotron radiation-based dynamic micro-CT for high-speed, non-destructive imaging.
- Employed lactose monohydrate (LMH) as a model powder for wet granulation experiments.
- Applied phase-retrieval algorithms to enhance image contrast and enable detailed analysis.
Main Results:
- Successfully captured the rapid microstructural evolution during LMH wet granulation (seconds timescale).
- Observed and quantified granule consolidation and the dynamic changes in internal porosity.
- Determined the influence of particle aggregates on the evolving granule porosity.
Conclusions:
- Synchrotron-based dynamic micro-CT is a powerful tool for real-time analysis of fast processes like wet granulation.
- This technique offers significant advantages over 2D and ex situ methods for understanding granule formation.
- The study provides crucial insights into the microstructural development influencing pharmaceutical granule quality.
More Related Videos
09:00Visualization of Failure and the Associated Grain-Scale Mechanical Behavior of Granular Soils under Shear using Synchrotron X-Ray Micro-Tomography
Published on: September 29, 2019
11:48Microfluidic Chips for In Situ Crystal X-ray Diffraction and In Situ Dynamic Light Scattering for Serial Crystallography
Published on: April 24, 2018