A novel algorithm to assess the quality of 12-lead ECG recordings: validation in a real telecardiology application
Jermana L de Moraes1,2, Gabriela M M Paixão3, Paulo R Gomes3
1Postgraduate Program of Electrical Engineering, Federal University of Minas Gerais, Belo Horizonte, Brazil.
Abstract:
Objective. Automatic detection of Electrocardiograms (ECG) quality is fundamental to minimize costs and risks related to delayed diagnosis due to low ECG quality. Most algorithms to assess ECG quality include non-intuitive parameters. Also, they were developed using data non-representative of a real-world scenario, in terms of pathological ECGs and overrepresentation of low-quality ECG. Therefore, we introduce an algorithm to assess 12-lead ECG quality, Noise Automatic Classification Algorithm (NACA) developed in Telehealth Network of Minas Gerais (TNMG).Approach. NACA estimates a signal-to-noise ratio (SNR) for each ECG lead, where 'signal' is an estimated heartbeat template, and 'noise' is the discrepancy between the template and the ECG heartbeat. Then, clinically-inspired rules based on SNR are used to classify the ECG as acceptable or unacceptable. NACA was compared with Quality Measurement Algorithm (QMA), the winner of Computing in Cardiology Challenge 2011 (ChallengeCinC) by using five metrics: sensitivity (Se), specificity (Sp), positive predictive value (PPV),F2, and cost reduction resulting from adoption of the algorithm. Two datasets were used for validation: TestTNMG, consisting of 34 310 ECGs received by TNMG (1% unacceptable and 50% pathological); ChallengeCinC, consisting of 1000 ECGs (23% unacceptable, higher than real-world scenario).Main results. Both algorithms reached a similar performance on ChallengeCinC, although NACA performed considerably better than QMA in TestTNMG (Se = 0.89 versus 0.21; Sp = 0.99 versus 0.98; PPV = 0.59 versus 0.08;F2= 0.76 versus 0.16 and cost reduction 2.3 ± 1.8% versus 0.3 ± 0.3%, respectively).Significance. Implementing of NACA in a telecardiology service results in evident health and financial benefits for the patients and the healthcare system.
More Related Videos
10:17Real-Time Cardiac Mapping with a Noninvasive Imageless Electrocardiographic Imaging System
Published on: April 11, 2025
18:11A Research Method For Detecting Transient Myocardial Ischemia In Patients With Suspected Acute Coronary Syndrome Using Continuous ST-segment Analysis
Published on: December 28, 2012
Related Concept Videos
Electrocardiogram
Three major waveforms are present in a typical ECG recording: the P wave, the QRS complex, and...
Electrocardiogram Fundamentals
An electrocardiogram (ECG) is a diagnostic tool for identifying cardiac conditions such as arrhythmias, conduction abnormalities, and myocardial ischemia.
Definition
An electrocardiogram (ECG) visualizes the heart's electrical activity by tracing the electrical movement associated with each heartbeat on a graph or monitor. As the heart beats, an electrical wave passes through it, correlating with the cardiac cycle events.
Parts of an ECG
An ECG utilizes electrodes on the skin...
Dysrhythmias V: Evaluating Dysrhythmias
Correlation between ECG and Cardiac Cycle
A cardiac action potential originates in the SA node and spreads throughout the atria and the AV node in approximately 0.03 seconds. This results in the P wave in an ECG and triggers atrial contraction. The action potential is then briefly slowed at the AV node, allowing the atria to contract and fill the ventricles with blood before...
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac...
Holter Monitor: 24-Hour Monitoring