Related Experiment Video
Updated: Aug 7, 2025

Occlusion of the Great and Small Saphenous Vein Using Copolymeric Glue Based on N-Butyl Cyanoacrylate and Methacryloxy Sulfolane
Published on: December 9, 2022
Consistent application of compression: An under-considered variable in the prevention of venous leg ulcers
Harrison J Shawa1,2, Sara E Dahle2,3, Roslyn Rivkah Isseroff1,2
1Dermatology Division, VA Northern California Health Care System, Mather, California, USA.
Abstract:
Venous leg ulcers, the most common leg ulcer, occur in patients with chronic venous insufficiency due to venous hypertension. Evidence supports the conservative treatment with lower extremity compression, ideally between 30-40 mm Hg. Pressures in this range provide enough force to partially collapse lower extremity veins without restricting arterial flow in patients without peripheral arterial disease. There are many options for applying such compression, and those who apply these devices have varying levels of training and backgrounds. In this quality improvement project, a single observer utilised a reusable pressure monitor to compare pressures applied using different devices by individuals in wound clinics with diverse training from specialties of dermatology, podiatry, and general surgery. Average compression was higher in the dermatology wound clinic (n = 153) compared to the general surgery clinic (n = 53) (35.7 ± 13.3 and 27.2 ± 8.0 mm Hg, respectively, p < 0.0001), and wraps applied by clinic staff (n = 194) were nearly twice as likely as a self-applied wrap (n = 71) to have pressures greater than 40 mm Hg (relative risk: 2.2, 95% confidence interval: 1.136-4.423, p = 0.02). Pressures were also dependent upon the specific compression device used, with CircAid®s (35.5 mm Hg, SD: 12.0 mm Hg, n = 159) providing higher average pressures than Sigvaris Compreflex (29.5 mm Hg, SD: 7.7 mm Hg, n = 53, p = 0.009) and Sigvaris Coolflex (25.2 mm Hg, SD: 8.0 mm Hg, n = 32, p < 0.0001). These results indicate that the device-provided pressure may be dependent on both the compression device and the background and training of the applicator. We propose that standardisation in the training of compression application and increased use of a point-of-care pressure monitor may improve the consistency of applied compression, thus improving adherence to treatment and outcomes in patients with chronic venous insufficiency.
More Related Videos
06:45Point-Of-Care Ultrasound Screening for Proximal Lower Extremity Deep Venous Thrombosis
Published on: February 10, 2023
09:04Synergizing Antegrade Endoscopic with Bridging Vein Harvesting for Improvement of Great Saphenous Vein Graft Quality from the Lower Leg
Published on: November 19, 2019
Related Concept Videos
Venous Thrombosis III: Interprofessional Care
Venous Thrombosis IV: Nursing Management
Varicose Veins II: Diagnostic Studies and Interprofessional Care
Peripheral Artery Disease V: Postoperative Nursing Management
Venous Thrombosis II: Clinical Manifestations and Diagnostic Studies
Varicose Veins I: Introduction